Robustness of Physiological Synchrony in Wearable Electrodermal Activity and Heart Rate as a Measure of Attentional Engagement to Movie Clips
Sensors · 10.03.2023 · 23 (6) · 3006
DOI: 10.3390/s23063006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 10.03.2023. Verfasst von Ivo V Stuldreher und 2 weiteren Autor:innen. Beteiligte Einrichtung: Human Performance, Netherlands Organisation for Applied Scientific Research (TNO), 3769 DE Soesterberg, The Netherlands. Hauptthemen laut MEDLINE: Galvanic Skin Response, Wearable Electronic Devices. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Netherlands Organisation for Applied Scientific Research, TNO’s Early Research Program Body-Brain Interaction.
Abstract (Originalsprache)
Individuals that pay attention to narrative stimuli show synchronized heart rate (HR) and electrodermal activity (EDA) responses. The degree to which this physiological synchrony occurs is related to attentional engagement. Factors that can influence attention, such as instructions, salience of the narrative stimulus and characteristics of the individual, affect physiological synchrony. The demonstrability of synchrony depends on the amount of data used in the analysis. We investigated how demonstrability of physiological synchrony varies with varying group size and stimulus duration. Thirty participants watched six 10 min movie clips while their HR and EDA were monitored using wearable sensors (Movisens EdaMove 4 and Wahoo Tickr, respectively). We calculated inter-subject correlations as a measure of synchrony. Group size and stimulus duration were varied by using data from subsets of the participants and movie clips in the analysis. We found that for HR, higher synchrony correlated significantly with the number of answers correct for questions about the movie, confirming that physiological synchrony is associated with attention. For both HR and EDA, with increasing amounts of data used, the percentage of participants with significant synchrony increased. Importantly, we found that it did not matter how the amount of data was increased. Increasing the group size or increasing the stimulus duration led to the same results. Initial comparisons with results from other studies suggest that our results do not only apply to our specific set of stimuli and participants. All in all, the current work can act as a guideline for future research, indicating the amount of data minimally needed for robust analysis of synchrony based on inter-subject correlations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Human Performance, Netherlands Organisation for Applied Scientific Research (TNO), 3769 DE Soesterberg, The Netherlands.
- Human Media Interaction, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, 7522 NB Enschede, The Netherlands.
- Human Machine Teaming, Netherlands Organisation for Applied Scientific Research (TNO), 3769 DE Soesterberg, The Netherlands.
- Artificial Intelligence, Faculty of Social Sciences, Radboud University, Thomas van Aquinostraat 4, 6525 GD Nijmegen, The Netherlands.
ORCID-Profile: Ivo V Stuldreher, Jan B F van Erp, Anne-Marie Brouwer
Förderung
- Netherlands Organisation for Applied Scientific Research
- TNO’s Early Research Program Body-Brain Interaction
Zitieren
APA
Stuldreher, I. V., van Erp, J. B. F., & Brouwer, A. M. (2023). Robustness of Physiological Synchrony in Wearable Electrodermal Activity and Heart Rate as a Measure of Attentional Engagement to Movie Clips. Sensors, 23(6), 3006. https://doi.org/10.3390/s23063006
Vancouver
Stuldreher IV, van Erp JBF, Brouwer AM. Robustness of Physiological Synchrony in Wearable Electrodermal Activity and Heart Rate as a Measure of Attentional Engagement to Movie Clips. Sensors. 2023;23(6):3006. doi:10.3390/s23063006
BibTeX
@article{Stuldreher2023,
author = {Stuldreher, Ivo V and van Erp, Jan B F and Brouwer, Anne-Marie},
title = {Robustness of Physiological Synchrony in Wearable Electrodermal Activity and Heart Rate as a Measure of Attentional Engagement to Movie Clips},
journal = {Sensors},
year = {2023},
volume = {23},
number = {6},
pages = {3006},
doi = {10.3390/s23063006}
}
EUVIMED