EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Modeling the Design Characteristics of Woven Textile Electrodes for long−Term ECG Monitoring

Peter J Brehm iD, Allison P Anderson iD

Sensors · 2023

DOI: 10.3390/s23020598 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Peter J Brehm und 1 weiteren Autor:innen. Beteiligte Einrichtung: Aerospace Engineering Department, University of Colorado, Boulder, CO 80309, USA. Hauptthemen laut MEDLINE: Electrocardiography, Textiles. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An electrocardiograph records the periodic voltage generated by the heart over time. There is growing demand to continuously monitor the ECG for proactive health care and human performance optimization. To meet this demand, new conductive textile electrodes are being developed which offer an attractive alternative to adhesive gel electrodes but they come with their own challenges. The key challenge with textile electrodes is that the relationship between the manufacturing parameters and the ECG measurement is not well understood, making design an iterative process without the ability to prospectively develop woven electrodes with optimized performance. Here we address this challenge by applying the traditional skin−electrode interface circuit model to woven electrodes by constructing a parameterized model of the ECG system. Then the unknown parameters of the system are solved for with an iterative MATLAB optimizer using measured data captured with the woven electrodes. The results of this novel analysis confirm that yarn conductivity and total conductive area reduce skin electrode impedance. The results also indicate that electrode skin pressure and moisture require further investigation. By closing this gap in development, textile electrodes can be better designed and manufactured to meet the demands of long−term ECG capture.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographyTextilesHumansElectrodesElectric ConductivityElectric Impedance

Stichwörter der Autor:innen

MATLABcircuit model impedanceconductive textile manufacturingelectrocardiographskin−electrode interface modeltransfer functionwoven electrode

Autor:innen und Institutionen

  • Aerospace Engineering Department, University of Colorado, Boulder, CO 80309, USA.

ORCID-Profile: Peter J Brehm, Allison P Anderson

Zitieren

APA

Brehm, P. J., & Anderson, A. P. (2023). Modeling the Design Characteristics of Woven Textile Electrodes for long−Term ECG Monitoring. Sensors. https://doi.org/10.3390/s23020598

Vancouver

Brehm PJ, Anderson AP. Modeling the Design Characteristics of Woven Textile Electrodes for long−Term ECG Monitoring. Sensors. 2023. doi:10.3390/s23020598

BibTeX
@article{Brehm2023,
  author = {Brehm, Peter J and Anderson, Allison P},
  title = {Modeling the Design Characteristics of Woven Textile Electrodes for long−Term ECG Monitoring},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23020598}
}