Comparison of a Wearable Accelerometer/Gyroscopic, Portable Gait Analysis System (LEGSYS+TM) to the Laboratory Standard of Static Motion Capture Camera Analysis
Sensors · 2023
DOI: 10.3390/s23010537 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Ryan Homes und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Sciences, The University of Queensland, Brisbane, QLD 4067, Australia. Hauptthemen laut MEDLINE: Gait Analysis, Wearable Electronic Devices. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Examination of gait patterns has been used to determine severity, intervention triage and prognostic measures for many health conditions. Methods that generate detailed gait data for clinical use are typically logistically constrained to a formal gait laboratory setting. This has led to an interest in portable analysis systems for near clinical or community-based assessments. The following study assessed with the wearable accelerometer/gyroscopic, gait analysis system (LEGSYS+TM) and the standard of static motion capture camera (MOCAP) analysis during a treadmill walk at three different walking speeds in healthy participants (n = 15). To compare each speed, 20 strides were selected from the MOCAP data and compared with the LEGSYS+ strides at the same time point. Both scatter and bland-Altman plots with accompanying linear regression analysis for each of the parameters. Each stride parameter showed minimal or a consistent difference between the LEGSYS+ and MOCAP, with the phase parameters showing inconsistencies between the systems. Overall, LEGSYS+ stride parameters can be used in the clinical setting, with the utility of phase parameters needing to be taken with caution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD 4067, Australia.
- School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, QLD 4072, Australia.
- ARC ITTC Joint Biomechanics, Queensland Unit for Advanced Shoulder Research, Movement Neuroscience Group, Injury Prevention Group, Exercise & Movement Science, School of Exercise and Nutrition Sciences, Queensland Unive…
ORCID-Profile: Ryan Homes, Wolbert Van den Hoorn, Mark Midwinter
Zitieren
APA
Homes, R., Clark, D., Moridzadeh, S., Tosovic, D., Van den Hoorn, W., Tucker, K., & Midwinter, M. (2023). Comparison of a Wearable Accelerometer/Gyroscopic, Portable Gait Analysis System (LEGSYS+TM) to the Laboratory Standard of Static Motion Capture Camera Analysis. Sensors. https://doi.org/10.3390/s23010537
Vancouver
Homes R, Clark D, Moridzadeh S, Tosovic D, Van den Hoorn W, Tucker K, et al. Comparison of a Wearable Accelerometer/Gyroscopic, Portable Gait Analysis System (LEGSYS+TM) to the Laboratory Standard of Static Motion Capture Camera Analysis. Sensors. 2023. doi:10.3390/s23010537
BibTeX
@article{Homes2023,
author = {Homes, Ryan and Clark, Devon and Moridzadeh, Sina and Tosovic, Danijel and Van den Hoorn, Wolbert and Tucker, Kylie and Midwinter, Mark},
title = {Comparison of a Wearable Accelerometer/Gyroscopic, Portable Gait Analysis System (LEGSYS+TM) to the Laboratory Standard of Static Motion Capture Camera Analysis},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23010537}
}
EUVIMED