Organic Acid Leaching of Black Mass with an LFP and NMC Mixed Chemistry
Recycling · 21.07.2025 · 10 (4) · 145
DOI: 10.3390/recycling10040145 ↗Kurz gefasst
Fachartikel in der Zeitschrift Recycling, online erschienen am 21.07.2025. Verfasst von Marc Simon Henderson und 3 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Future Battery Industries CRC (FBI-CRC, as part of the Australian Government Cooperative Research Centres Program), Curtin University, Tescan Clara FESEM with Oxford instrumentation.
Abstract (Originalsprache)
There is an increasing demand for the development of efficient and sustainable battery recycling processes. Currently, many recycling processes rely on toxic inorganic acids to recover materials from high-value battery chemistries such as lithium nickel manganese cobalt oxides (NMCs) and lithium cobalt oxide (LCOs). However, as cell manufacturers seek more cost-effective battery chemistries, the value of the spent battery value chain is increasingly diluted by chemistries such as lithium iron phosphate (LFPs). These cheaper alternatives present a difficulty when recycling, as current recycling processes are geared towards dealing with high-value chemistries; thus, the current processes become less economical. To date, much research is focused on treating a single battery chemistry; however, often, the feed material entering a battery recycling facility is contaminated with other battery chemistries, e.g., LFP feed contaminated with NMC, LCO, or LMOs. This research aims to selectively leach various battery chemistries out of a mixed feed material with the aid of a green organic acid, namely oxalic acid. When operating at the optimal conditions (2% solids, 0.25 M oxalic acid, natural pH around 1.15, 25 °C, 60 min), this research has proven that oxalic acid can be used to selectively dissolve 95.58% and 93.57% of Li and P, respectively, from a mixed LFP-NMC mixed feed, all while only extracting 12.83% of Fe and 8.43% of Mn, with no Co and Ni being detected in solution. Along with the high degree of selectivity, this research has also demonstrated, through varying the pH, that the selectivity of the leaching system can be altered. It was determined that at pH 0.5 the system dissolved both the NMC and LFP chemistries; at a pH of 1.15, the LFP chemistry (Li and P) was selectively targeted. Finally, at a pH of 4, the NMC chemistry (Ni, Co and Mn) was selectively dissolved.
Förderung
- The Future Battery Industries CRC (FBI-CRC, as part of the Australian Government Cooperative Research Centres Program)
- Curtin University
- Tescan Clara FESEM with Oxford instrumentation
Zitieren
APA
Henderson, M. S., Beh, C. C., Oraby, E., & Eksteen, J. (2025). Organic Acid Leaching of Black Mass with an LFP and NMC Mixed Chemistry. Recycling, 10(4), 145. https://doi.org/10.3390/recycling10040145
Vancouver
Henderson MS, Beh CC, Oraby E, Eksteen J. Organic Acid Leaching of Black Mass with an LFP and NMC Mixed Chemistry. Recycling. 2025;10(4):145. doi:10.3390/recycling10040145
BibTeX
@article{Henderson2025,
author = {Henderson, Marc Simon and Beh, Chau Chun and Oraby, Elsayed and Eksteen, Jacques},
title = {Organic Acid Leaching of Black Mass with an LFP and NMC Mixed Chemistry},
journal = {Recycling},
year = {2025},
volume = {10},
number = {4},
pages = {145},
doi = {10.3390/recycling10040145}
}