Effect of Type of Cement, Fabrication Technique, and Cyclic Loading on the Marginal Accuracy of Lithium Disilicate Crowns

Salah A. Yousief, Hend Mohamed Elsayed, Abdulrazak Mahmoud Fayed, Roua Mohammed Y. Almadani, Mohammad Abdullah Alqhtani, Ahmed Mohammed Sleem Abdelglel, Khalid Dhafer Alhendi, Sokina Yosef Abdulmalik, Sarah Salah Gaafar, Ahmed Ibrahim Mahrous, Ebaa Ibrahim Alagha, Mahmoud Darwish

Prosthesis · 21.04.2026 · 8 (4) · 42

DOI: 10.3390/prosthesis8040042 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Prosthesis, online erschienen am 21.04.2026. Verfasst von Salah A. Yousief und 11 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and aim: The influence of fabrication techniques, cement type, and cyclic loading on the marginal adaptation of lithium disilicate crowns remains a clinical concern that may affect their long-term performance. This study aimed to evaluate the effects of cyclic loading and cement type on the marginal fit of milled and pressed lithium disilicate crowns.

Methods

Twenty lithium disilicate crowns were fabricated and divided into two groups based on the manufacturing technique: milled and pressed (n = 10 each). Each group was further subdivided according to the cement type: resin or resin-modified glass ionomer (n = 5 per group). Crowns were cemented on standardized epoxy resin dies, and the marginal gap was measured using a stereomicroscope before and after cyclic loading. Cyclic loading was performed at 50 N for 37,000 cycles. Data were statistically analyzed using a three-way ANOVA (α = 0.05).

Results

Milled crowns showed marginal gaps ranging from 52 to 57 µm, whereas the pressed crowns exhibited smaller gaps ranging from 39 to 47 µm. Neither the cement type nor the cyclic loading produced a significant difference in the marginal gap values (p > 0.05).

Conclusions

Pressed lithium disilicate crowns exhibited superior marginal adaptation compared with the milled crowns. Neither the type of cement nor the cyclic loading had a significant effect on the marginal gap. Both fabrication techniques yielded clinically acceptable fits (

Zitieren

APA

Yousief, S. A., Elsayed, H. M., Fayed, A. M., Almadani, R. M. Y., Alqhtani, M. A., Abdelglel, A. M. S., Alhendi, K. D., Abdulmalik, S. Y., Gaafar, S. S., Mahrous, A. I., Alagha, E. I., & Darwish, M. (2026). Effect of Type of Cement, Fabrication Technique, and Cyclic Loading on the Marginal Accuracy of Lithium Disilicate Crowns. Prosthesis, 8(4), 42. https://doi.org/10.3390/prosthesis8040042

Vancouver

Yousief SA, Elsayed HM, Fayed AM, Almadani RMY, Alqhtani MA, Abdelglel AMS, et al. Effect of Type of Cement, Fabrication Technique, and Cyclic Loading on the Marginal Accuracy of Lithium Disilicate Crowns. Prosthesis. 2026;8(4):42. doi:10.3390/prosthesis8040042

BibTeX
@article{Yousief2026,
  author = {Yousief, Salah A. and Elsayed, Hend Mohamed and Fayed, Abdulrazak Mahmoud and Almadani, Roua Mohammed Y. and Alqhtani, Mohammad Abdullah and Abdelglel, Ahmed Mohammed Sleem and Alhendi, Khalid Dhafer and Abdulmalik, Sokina Yosef and Gaafar, Sarah Salah and Mahrous, Ahmed Ibrahim and Alagha, Ebaa Ibrahim and Darwish, Mahmoud},
  title = {Effect of Type of Cement, Fabrication Technique, and Cyclic Loading on the Marginal Accuracy of Lithium Disilicate Crowns},
  journal = {Prosthesis},
  year = {2026},
  volume = {8},
  number = {4},
  pages = {42},
  doi = {10.3390/prosthesis8040042}
}
Kostenlos starten →