Influence of intraoral scanner type on the marginal fit of digitally fabricated lithium disilicate crowns
Frontiers in Dental Medicine · 01.07.2026 · 7
DOI: 10.3389/fdmed.2026.1838235 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Dental Medicine, online erschienen am 01.07.2026. Verfasst von Mark Austin V Adriatico und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Dental Medicine, University of Nevada, Las Vegas, NV, United States. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
The accuracy of restorations fabricated through digital workflows is partially determined by the intraoral scanner utilized. This study evaluated the marginal fit of digitally fabricated lithium disilicate single crowns produced using two intraoral scanners: the iTero® Element and the Planmeca® Emerald.
Methods
Eleven non-carious molar teeth were prepared for full-coverage lithium disilicate crowns and scanned with both intraoral scanners. Restorations were designed using Romexis software and milled with a Planmeca® milling unit. Marginal fit, defined as the vertical discrepancy between the restoration margin and the prepared tooth surface, was measured at six locations per crown using a digital microscope at 80× magnification. Results and discussion Crowns fabricated from iTero® scans showed more consistent measurements, whereas those from Planmeca® scans showed greater variability. The mean marginal discrepancy was 51.27 µm for the iTero® group and 73.18 µm for the Planmeca® group. Although the iTero® group exhibited a lower mean marginal discrepancy, the difference between groups was statistically significant ( p = 0.032). All restorations were within the clinically acceptable marginal discrepancy range (<120 µm). Within the limitations of this in vitro study, both intraoral scanners produced lithium disilicate crowns with clinically acceptable marginal fit, and statistically significant difference was observed between the two systems.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Dental Medicine, University of Nevada, Las Vegas, NV, United States.
Zitieren
APA
Adriatico, M. A. V., Tran, N. N. P., & Abubakr, N. H. (2026). Influence of intraoral scanner type on the marginal fit of digitally fabricated lithium disilicate crowns. Frontiers in Dental Medicine, 7. https://doi.org/10.3389/fdmed.2026.1838235
Vancouver
Adriatico MAV, Tran NNP, Abubakr NH. Influence of intraoral scanner type on the marginal fit of digitally fabricated lithium disilicate crowns. Frontiers in Dental Medicine. 2026;7. doi:10.3389/fdmed.2026.1838235
BibTeX
@article{Adriatico2026,
author = {Adriatico, Mark Austin V and Tran, Nghi Ngoc Phuong and Abubakr, Neamat H},
title = {Influence of intraoral scanner type on the marginal fit of digitally fabricated lithium disilicate crowns},
journal = {Frontiers in Dental Medicine},
year = {2026},
volume = {7},
doi = {10.3389/fdmed.2026.1838235}
}
EUVIMED