Performance and Optimization of a Solar-Assisted Air-Source Heat Pump System for Wellhead Heating in a High-Pressure Gas Field of Northwestern China
Processes · 17.11.2026 · 14 (22) · 3692
DOI: 10.3390/pr14223692 ↗Kurz gefasst
Fachartikel in der Zeitschrift Processes, online erschienen am 17.11.2026. Verfasst von Binyuan Rao und 7 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Major Project for Novel Oil and Gas Exploration and Development: Low-Carbon and Zero-Carbon Oilfield Demonstration.
Abstract (Originalsprache)
Wellhead heating is indispensable for high-pressure gas wells because the temperature drop caused by two-stage throttling brings the gas close to the hydrate formation temperature. The existing air-source heat pump (ASHP)-based heating system of a gas field in Northwestern China consumes 1,314,000 kWh of electricity every year, and its performance degrades severely at ambient temperatures down to −25 °C. To reduce the energy consumption due to wellhead heating, a solar-assisted air-source heat pump (SA-ASHP) system was proposed and investigated in this work. Two solar collector technologies, namely dish solar collectors and evacuated-tube collectors, were coupled with the ASHP, and TRNSYS models of both configurations were established together with a reference model of the existing ASHP system. The ASHP model was validated against field measurements with the part-load factor, and the deviation between the simulated and the metered August electricity consumption of the three wells is only 4.43%. The collector area, the storage tank volume and the heat-transfer-oil flow rates were then optimized with the life cycle cost as the objective under the constraint that the annual heating guarantee rate is not lower than 99.5%. The results show that the optimal dish collector scheme consists of eight collectors (800 m2) and an 80 m3 storage tank, which reduces the annual electricity consumption to 294,817 kWh, which is 22.4% of the direct electric heating scheme, raises the system COP to 4.46, saves 39.6 × 104 CNY of electricity cost per year and achieves the highest return on investment of 4.31%. The optimal evacuated-tube collector scheme requires 800 m2 of collector area and a 45 m3 storage tank and gives a return on investment of 4.05%. The SA-ASHP with dish collector scheme is therefore recommended as the most energy-efficient heating scheme, with the highest return on investment, for the studied gas field.
Förderung
- National Science and Technology Major Project for Novel Oil and Gas Exploration and Development: Low-Carbon and Zero-Carbon Oilfield Demonstration
Zitieren
APA
Rao, B., Li, Y., Zhao, G., Bai, Y., Liu, N., Liu, Q., Chen, X., & Zhang, Y. (2026). Performance and Optimization of a Solar-Assisted Air-Source Heat Pump System for Wellhead Heating in a High-Pressure Gas Field of Northwestern China. Processes, 14(22), 3692. https://doi.org/10.3390/pr14223692
Vancouver
Rao B, Li Y, Zhao G, Bai Y, Liu N, Liu Q, et al. Performance and Optimization of a Solar-Assisted Air-Source Heat Pump System for Wellhead Heating in a High-Pressure Gas Field of Northwestern China. Processes. 2026;14(22):3692. doi:10.3390/pr14223692
BibTeX
@article{Rao2026,
author = {Rao, Binyuan and Li, Yingjie and Zhao, Guangdan and Bai, Yongle and Liu, Naipeng and Liu, Qin and Chen, Xiaoling and Zhang, Yongxing},
title = {Performance and Optimization of a Solar-Assisted Air-Source Heat Pump System for Wellhead Heating in a High-Pressure Gas Field of Northwestern China},
journal = {Processes},
year = {2026},
volume = {14},
number = {22},
pages = {3692},
doi = {10.3390/pr14223692}
}
EUVIMED