Performance Analysis of a Solar-Assisted Air Source Heat Pump with Cascaded Latent Heat Storage and Utilization for Building Heating

Yuliang Zhong, Yimeng Sun, Lu Wang, Bowen Xu, Jiale Chai, Xiangfei Kong

Buildings · 14.04.2026 · 16 (8) · 1541

DOI: 10.3390/buildings16081541 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Buildings, online erschienen am 14.04.2026. Verfasst von Yuliang Zhong und 5 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Science and Technology Research Project of Colleges and Universities in Hebei Province, Central-Local Cooperation Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The solar-assisted air source heat pump (SAHP) is a key technology of low carbon heating. However, the SAHP is still inefficient and unstable at low temperatures. Cascaded latent heat storage (CLHS) can store multi-stage thermal energy, which provides the possibility for the multiple utilization of solar energy. Hence, this paper proposed the SAHP integrated with CLHS for building heating. The high-temperature and medium-temperature latent heat storage (LHS) units are used for direct heating, and the low-temperature LHS unit preheats the air for the air source heat pump (ASHP). The thermal performance of the CLHS device is evaluated through combined numerical simulations and experimental tests. Results show that the average heat storage rate of the cascaded system is 61.1% higher than that of a conventional single-stage LHS unit. The heat storage uniformity of CLHS gradually improves with increasing inlet flow rate, but shows a trend of first increasing and then decreasing with the increase in fluid inlet temperature. Among the three tested levels, 80 °C was found to be the most uniform heat storage of the CLHS device. The performance of the system was further analyzed using TRNSYS to assess seasonal building heating performance. The overall efficiencies of the high/middle/low temperature LHS units are 93.6%, 81.6% and 94.3%, respectively. And the solar heat supply accounts for 70.8% of the total heat supply of the system. Compared with the non-preheating system where the low-temperature LHS unit is removed, the COP of the graded heating system is increased by 18.3%, and the energy consumption is reduced by 16.6%. Further parametric optimization based on the Hooke–Jeeves method reduces total system energy consumption by 20.7% and associated pollutant emissions by 20.6% compared with the pre-optimization system. The findings provide practical insights into the application of CLHS in solar-assisted heat pump systems for building heating.

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Research Project of Colleges and Universities in Hebei Province
  • Central-Local Cooperation Program

Zitieren

APA

Zhong, Y., Sun, Y., Wang, L., Xu, B., Chai, J., & Kong, X. (2026). Performance Analysis of a Solar-Assisted Air Source Heat Pump with Cascaded Latent Heat Storage and Utilization for Building Heating. Buildings, 16(8), 1541. https://doi.org/10.3390/buildings16081541

Vancouver

Zhong Y, Sun Y, Wang L, Xu B, Chai J, Kong X. Performance Analysis of a Solar-Assisted Air Source Heat Pump with Cascaded Latent Heat Storage and Utilization for Building Heating. Buildings. 2026;16(8):1541. doi:10.3390/buildings16081541

BibTeX
@article{Zhong2026,
  author = {Zhong, Yuliang and Sun, Yimeng and Wang, Lu and Xu, Bowen and Chai, Jiale and Kong, Xiangfei},
  title = {Performance Analysis of a Solar-Assisted Air Source Heat Pump with Cascaded Latent Heat Storage and Utilization for Building Heating},
  journal = {Buildings},
  year = {2026},
  volume = {16},
  number = {8},
  pages = {1541},
  doi = {10.3390/buildings16081541}
}
Kostenlos starten →