EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Research on Impurity Separation Behavior During Pre-Storage Paddy Cleaning with CFD-DPM

Zhiqi Hou, Can Shu, Nianwu Wei, Xinfeng Hu, Menghao Zhao, Dong Yang, Liu Yang

Processes · 03.11.2026 · 14 (21) · 3545

DOI: 10.3390/pr14213545 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 03.11.2026. Verfasst von Zhiqi Hou und 6 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Youth Project of the Natural Science Foundation of Hubei Province, Hubei provincial Grain Bureau Science Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Paddy grains require impurity removal before storage, and cyclone air separation is the final stage for removing lightweight impurities. In this study, a three-dimensional computational fluid dynamics–discrete phase model (CFD–DPM) was established to investigate impurity separation in a cyclone air separation device. The Reynolds stress model (RSM) was used for the continuous air phase, and the discrete phase model (DPM) was used to track impurity particles. Simulations were performed at an inlet velocity of 9 m/s, corresponding to a Reynolds number (Re) of approximately 1.84 × 105 based on an inlet hydraulic diameter of 0.299 m. Three structural parameters were investigated: the dust outlet diameter (Ddo = 454–654 mm), conical section length (Lcs = 1476–1876 mm), and impurity capture diameter (Dic = 240–440 mm). Particle tracking showed four main stages: particle entry, downward spiral motion, size-dependent separation, and discharge. When Ddo increased from 454 to 654 mm, separation efficiency decreased from 88.75% to 55.46%, while the pressure drop decreased from 223.65 to 161.09 Pa. Increasing Lcs from 1476 to 1876 mm increased the separation efficiency from 44.46% to 82.87%, with the pressure drop increasing from 170.13 to 208.90 Pa. Increasing Dic from 240 to 440 mm reduced the separation efficiency from about 85% to 53%, while the pressure drop decreased from about 205 to 173 Pa. These results show that the structural parameters affect separation performance by changing the swirling flow and particle migration path.

Förderung

  • Youth Project of the Natural Science Foundation of Hubei Province
  • Hubei provincial Grain Bureau Science Project

Zitieren

APA

Hou, Z., Shu, C., Wei, N., Hu, X., Zhao, M., Yang, D., & Yang, L. (2026). Research on Impurity Separation Behavior During Pre-Storage Paddy Cleaning with CFD-DPM. Processes, 14(21), 3545. https://doi.org/10.3390/pr14213545

Vancouver

Hou Z, Shu C, Wei N, Hu X, Zhao M, Yang D, et al. Research on Impurity Separation Behavior During Pre-Storage Paddy Cleaning with CFD-DPM. Processes. 2026;14(21):3545. doi:10.3390/pr14213545

BibTeX
@article{Hou2026,
  author = {Hou, Zhiqi and Shu, Can and Wei, Nianwu and Hu, Xinfeng and Zhao, Menghao and Yang, Dong and Yang, Liu},
  title = {Research on Impurity Separation Behavior During Pre-Storage Paddy Cleaning with CFD-DPM},
  journal = {Processes},
  year = {2026},
  volume = {14},
  number = {21},
  pages = {3545},
  doi = {10.3390/pr14213545}
}
Kostenlos starten →