EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Flow Coefficient as a Normalising Operating Parameter for Comparison of Drop-in Fluid Replacement in Centrifugal Compressors

Jordan Dickenson, James R. Bull, Jovana Radulovic, James M. Buick

Processes · 23.10.2026 · 14 (21) · 3404

DOI: 10.3390/pr14213404 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 23.10.2026. Verfasst von Jordan Dickenson und 3 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The phase-out of high-GWP refrigerants means working fluids are increasingly replaced in compressors already designed and sized for the original fluid. Assessing the fluid replacement in a fixed geometry is complicated by the choice of operating parameter: at a matched mass flow rate, fluids with different densities will exhibit different volumetric flow. This study uses the flow coefficient as the main flow-side operating parameter, with the mass flow rate being calculated individually for each fluid and rotational speed so that all fluids are compared at the matched non-dimensional operating point. Eight working fluids—air, nitrogen, argon, carbon dioxide, R22, R134a, R1234yf and R1234ze(E)—were simulated in a single fixed-geometry centrifugal impeller geometry using ANSYS CFX 2024 R2 across six rotational speeds from 10,000 to 20,000 RPM and six flow coefficients. The efficiency optima of all eight fluids cluster to a common flow coefficient between 0.0636 and 0.0697. However, the width of the characteristic and the onset of choke remain fluid-dependent. While the low-density fluids operate over the full range of flow coefficients, the refrigerants exhibit choke at the higher end of the flow coefficient range, a feature which increases with the rotational velocity.

Zitieren

APA

Dickenson, J., Bull, J. R., Radulovic, J., & Buick, J. M. (2026). Flow Coefficient as a Normalising Operating Parameter for Comparison of Drop-in Fluid Replacement in Centrifugal Compressors. Processes, 14(21), 3404. https://doi.org/10.3390/pr14213404

Vancouver

Dickenson J, Bull JR, Radulovic J, Buick JM. Flow Coefficient as a Normalising Operating Parameter for Comparison of Drop-in Fluid Replacement in Centrifugal Compressors. Processes. 2026;14(21):3404. doi:10.3390/pr14213404

BibTeX
@article{Dickenson2026,
  author = {Dickenson, Jordan and Bull, James R. and Radulovic, Jovana and Buick, James M.},
  title = {Flow Coefficient as a Normalising Operating Parameter for Comparison of Drop-in Fluid Replacement in Centrifugal Compressors},
  journal = {Processes},
  year = {2026},
  volume = {14},
  number = {21},
  pages = {3404},
  doi = {10.3390/pr14213404}
}
Kostenlos starten →