Comparative Analysis of Direct Drop-In Fluid Replacement for a Centrifugal Compression System

Jordan Dickenson, James R. Bull, Jovana Radulovic, James M. Buick

Processes · 27.07.2026 · 14 (15) · 2412

DOI: 10.3390/pr14152412 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 27.07.2026. Verfasst von Jordan Dickenson und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The phasing out of high-GWP refrigerants and the growing diversity of working fluids used across heat pumps, refrigeration systems, and closed-cycle power applications have made drop-in fluid replacement a question of significant practical interest. Centrifugal compressors are designed around the thermophysical properties of a specific fluid, and the performance penalty is incurred when working fluid is replaced without redesigning the impeller. This study presents a CFD comparison of direct drop-in fluid replacement in a fixed geometry centrifugal compression system. Eight working fluids that span the property range relevant to current drop-in substitutions are evaluated: air, nitrogen, argon, carbon dioxide, R22, R134a, R1234yf, and R1234ze(E). A reference centrifugal impeller was reconstructed in ANSYS BladeGen, meshed in ANSYS TurboGrid using the Automatic Topology and Meshing method, and simulated in ANSYS CFX (2024 R2) as a single periodic passage with Frozen Rotor interfaces and Spalart–Allmaras turbulence closure. Performance maps were generated for each fluid across a range of rotational speeds and mass flow rates, with a common inlet reference condition applied across all cases to isolate the influence of fluid properties from an inlet state. The resulting dataset enables a like-for-like comparison of pressure ratio, efficiency, and shaft power requirement, providing a basis for assessing the aerodynamic implications of drop-in fluid substitution in centrifugal compression systems. Air, nitrogen, argon and carbon dioxide achieved similar peak efficiencies (~88%) and comparable pressure ratios (PR), indicating they can be used as drop-in substitutes without performance loss. Refrigerants R1234yf and R1234ze(E) matched R134a in efficiency (peak ~90%) while offering higher pressure ratios and significantly lower power requirements at peak efficiency. At 20,000 RPM and a mass flow rate of 2 kg/s, compared to a PR of 1.45 for air, nitrogen, carbon dioxide and argon achieved PRs of 1.4, 1.9 and 2.4, respectively. At the same settings, R134a and R1234 refrigerants reached PRs of 5 and 6, respectively. The power requirement was ~8 × 104 W for air and similar fluids, and ~11 × 104 W for refrigerants.

Zitieren

APA

Dickenson, J., Bull, J. R., Radulovic, J., & Buick, J. M. (2026). Comparative Analysis of Direct Drop-In Fluid Replacement for a Centrifugal Compression System. Processes, 14(15), 2412. https://doi.org/10.3390/pr14152412

Vancouver

Dickenson J, Bull JR, Radulovic J, Buick JM. Comparative Analysis of Direct Drop-In Fluid Replacement for a Centrifugal Compression System. Processes. 2026;14(15):2412. doi:10.3390/pr14152412

BibTeX
@article{Dickenson2026,
  author = {Dickenson, Jordan and Bull, James R. and Radulovic, Jovana and Buick, James M.},
  title = {Comparative Analysis of Direct Drop-In Fluid Replacement for a Centrifugal Compression System},
  journal = {Processes},
  year = {2026},
  volume = {14},
  number = {15},
  pages = {2412},
  doi = {10.3390/pr14152412}
}
Kostenlos starten →