CFD-Based Evaluation of a Serial Air-Supply Strategy in a Continuous Annular Cooler for Uniform Sinter Discharge Temperature
Processes · 18.08.2026 · 14 (16) · 2630
DOI: 10.3390/pr14162630 ↗Kurz gefasst
Fachartikel in der Zeitschrift Processes, online erschienen am 18.08.2026. Verfasst von Jiayu Pi und 6 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ironmaking Engineering Department of Sinosteel Equipment & Engineering Co., Ltd..
Abstract (Originalsprache)
Non-uniform discharge temperature during sinter cooling is a practical issue in ironmaking, as local overheating may increase the thermal load on downstream conveying equipment. To mitigate insufficient cooling in the upper sinter bed under the conventional bottom-blowing mode, this study developed a three-dimensional transient CFD model for an industrial continuous annular cooler and optimized the air-supply strategy in Zones IV and V. Under the conventional condition, ambient air is supplied independently to Zones IV and V from the bottom wind boxes. In the novel air-supply strategy, while keeping the total fresh cooling-air flow rate in the final cooling region unchanged, ambient air is introduced from the upper side of Zone V and discharged from its bottom; the outlet gas from Zone V is then supplied to the bottom of Zone IV, forming a serial air-supply path. The results show that the novel arrangement improves the spatial matching between the cooling gas and the sinter bed during final cooling and suppresses the local high-temperature region near the discharge end. The maximum discharge temperature decreases from 459 K to 410 K, below the process limit of 423 K, while the average discharge temperature decreases from 377 K to 364 K. Based on the enthalpy-flow difference calculation, the predicted recoverable waste heat also increases under the novel condition. These findings suggest that redesigning the gas-flow route in the final cooling region can effectively enhance the uniformity of the discharge temperature in industrial annular coolers.
Förderung
- Ironmaking Engineering Department of Sinosteel Equipment & Engineering Co., Ltd.
Zitieren
APA
Pi, J., Li, H., Xie, J., Wang, L., Liu, H., Dang, L., & Wei, H. (2026). CFD-Based Evaluation of a Serial Air-Supply Strategy in a Continuous Annular Cooler for Uniform Sinter Discharge Temperature. Processes, 14(16), 2630. https://doi.org/10.3390/pr14162630
Vancouver
Pi J, Li H, Xie J, Wang L, Liu H, Dang L, et al. CFD-Based Evaluation of a Serial Air-Supply Strategy in a Continuous Annular Cooler for Uniform Sinter Discharge Temperature. Processes. 2026;14(16):2630. doi:10.3390/pr14162630
BibTeX
@article{Pi2026,
author = {Pi, Jiayu and Li, Hui and Xie, Jingxuan and Wang, Liang and Liu, Hongfei and Dang, Leping and Wei, Hongyuan},
title = {CFD-Based Evaluation of a Serial Air-Supply Strategy in a Continuous Annular Cooler for Uniform Sinter Discharge Temperature},
journal = {Processes},
year = {2026},
volume = {14},
number = {16},
pages = {2630},
doi = {10.3390/pr14162630}
}
EUVIMED