EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Case Study: Impacts of Air-Conditioner Air Supply Strategy on Thermal Environment and Energy Consumption in Offices Using BES–CFD Co-Simulation

Luhan Wang, Guannan Li, Jiajia Gao, Xi Fang, Chongchong Wang, Chenglong Xiong

Sensors · 27.06.2023 · 23 (13) · 5958

DOI: 10.3390/s23135958 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 27.06.2023. Verfasst von Luhan Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Urban Construction, Wuhan University of Science and Technology, Wuhan 430065, China. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key Laboratory of Low-grade Energy Utilization Technologies and Systems of Ministry of Education of China (Chongqing University), State Key Laboratory of Green Building in Western China, Anhui Province Key Laboratory of Intelligent Building and Building Energy-saving.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Due to energy constraints and people’s increasing requirements for indoor thermal comfort, improving energy efficiency while ensuring thermal comfort has become the focus of research in the design and operation of HVAC systems. This study took office rooms with few people occupying them in Wuhan as the research object. The EnergyPlus-Fluent co-simulation method was used to study the impact of 12 forms of air distribution on the thermal environment and air-conditioner energy consumption. The results indicate that 3 m/s supply air velocity and 45° supply air angle are more suitable for the case model in this study. The EnergyPlus-Fluent co-simulation method used in this paper provides a reference for the study of indoor environments in offices with few people occupying them.

Schlagwörter

Stichwörter der Autor:innen

air conditionerair distributionsbuilding energy simulation (BES)computational fluid dynamics (CFD)energy consumptionthermal environment

Autor:innen und Institutionen

  • School of Urban Construction, Wuhan University of Science and Technology, Wuhan 430065, China.
  • Anhui Province Key Laboratory of Intelligent Building and Building Energy-Saving, Anhui Jianzhu University, Hefei 230601, China.
  • Key Laboratory of Low-Grade Energy Utilization Technologies and Systems (Chongqing University), Ministry of Education of China, Chongqing University, Chongqing 400044, China.
  • State Key Laboratory of Green Building in Western China, Xi'an University of Architecture & Technology, Xi'an 710055, China.
  • Hubei Provincial Engineering Research Center of Urban Regeneration, Wuhan University of Science and Technology, Wuhan 430065, China.
  • College of Civil Engineering, Hunan University, Changsha 410082, China.

Förderung

  • Key Laboratory of Low-grade Energy Utilization Technologies and Systems of Ministry of Education of China (Chongqing University)
  • State Key Laboratory of Green Building in Western China
  • Anhui Province Key Laboratory of Intelligent Building and Building Energy-saving
  • Wuhan University of Science and Technology
  • 2021 Construction Technology Plan Project of Hubei Province
  • Excellent Young and Middle-aged Talent in Universities of Hubei, China

Zitieren

APA

Wang, L., Li, G., Gao, J., Fang, X., Wang, C., & Xiong, C. (2023). Case Study: Impacts of Air-Conditioner Air Supply Strategy on Thermal Environment and Energy Consumption in Offices Using BES–CFD Co-Simulation. Sensors, 23(13), 5958. https://doi.org/10.3390/s23135958

Vancouver

Wang L, Li G, Gao J, Fang X, Wang C, Xiong C. Case Study: Impacts of Air-Conditioner Air Supply Strategy on Thermal Environment and Energy Consumption in Offices Using BES–CFD Co-Simulation. Sensors. 2023;23(13):5958. doi:10.3390/s23135958

BibTeX
@article{Wang2023,
  author = {Wang, Luhan and Li, Guannan and Gao, Jiajia and Fang, Xi and Wang, Chongchong and Xiong, Chenglong},
  title = {Case Study: Impacts of Air-Conditioner Air Supply Strategy on Thermal Environment and Energy Consumption in Offices Using BES–CFD Co-Simulation},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {13},
  pages = {5958},
  doi = {10.3390/s23135958}
}
Kostenlos starten →