EUVIMEDScopri EUVIMED
Open access · CC BY 4.0

Intelligent Diagnosis Method for Constrained Primary Frequency Regulation Capacity of Coal-Fired Units Based on ISO-MLRF

Yuliang Dong, Hongkun Lv, Huahua Wu, Jinghui Yang, Zhenya Lai, Yi Zhang, Jing Li, Dongyu Hua

Processes · 2026-05-20 · 14 (10) · 1658

DOI: 10.3390/pr14101658 ↗

At a glance

Journal article in Processes, published online on 2026-05-20. Written by Yuliang Dong and 7 co-authors. 33 references. The full text is freely available (open access, CC BY 4.0). Funded by: State Grid Zhejiang Electric Power Co., Ltd..

AbstractDati bibliograficiCiteRelated studies

Abstract (original language)

To address the challenges of low diagnostic accuracy of constrained primary frequency regulating (PFR) capacity for coal-fired units due to complex and strongly coupled restricting factors, an intelligent diagnosis method based on an improved snake optimizer-based multi-label random forest classification algorithm is proposed. By analyzing the factors restricting PFR capability, a set of characterization parameters and constraint factors for unit regulating capacity is established. The snake optimizer is enhanced by introducing dynamic update mechanisms and novel search strategies to improve its convergence speed and accuracy. The improved algorithm is then applied to optimize the hyperparameters of the multi-label random forest algorithm, enabling online diagnosis of PFR capacity limitations. Simulation results demonstrate that the proposed algorithm exhibits superior convergence performance, with lower medians of false alarm rate and missing alarm rate across all labels, coupled with reduced result dispersion compared to alternative algorithms. Tests on real operational data show an average false alarm rate of 0.029% and an average missing alarm rate of 0.053 for all labels. The results indicate that the proposed method is feasible and effective, enabling accurate online diagnosis of constrained PFR capacity of coal-fired units.

Funding

  • State Grid Zhejiang Electric Power Co., Ltd.

Cite

APA

Dong, Y., Lv, H., Wu, H., Yang, J., Lai, Z., Zhang, Y., Li, J., & Hua, D. (2026). Intelligent Diagnosis Method for Constrained Primary Frequency Regulation Capacity of Coal-Fired Units Based on ISO-MLRF. Processes, 14(10), 1658. https://doi.org/10.3390/pr14101658

Vancouver

Dong Y, Lv H, Wu H, Yang J, Lai Z, Zhang Y, et al. Intelligent Diagnosis Method for Constrained Primary Frequency Regulation Capacity of Coal-Fired Units Based on ISO-MLRF. Processes. 2026;14(10):1658. doi:10.3390/pr14101658

BibTeX
@article{Dong2026,
  author = {Dong, Yuliang and Lv, Hongkun and Wu, Huahua and Yang, Jinghui and Lai, Zhenya and Zhang, Yi and Li, Jing and Hua, Dongyu},
  title = {Intelligent Diagnosis Method for Constrained Primary Frequency Regulation Capacity of Coal-Fired Units Based on ISO-MLRF},
  journal = {Processes},
  year = {2026},
  volume = {14},
  number = {10},
  pages = {1658},
  doi = {10.3390/pr14101658}
}
Start for free →