EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Adaptive Virtual Impedance Fault Overcurrent Suppression Method and Reactive Power Support Method with Frozen Reactive Power–Voltage Droop Control for Grid-Forming Converters

Chengshuai Li, Zirui Dong, Shuolin Zhang, Longfei Mu, Jiahao Liu, Jiafei Liu, Qian Kai

Processes · 19.12.2025 · 14 (1) · 9

DOI: 10.3390/pr14010009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 19.12.2025. Verfasst von Chengshuai Li und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the rapid development of new energy, high-proportion new energy power systems have significantly reduced inertia and voltage support capacity, facing severe stability challenges. Virtual Synchronous Generator (VSG) control, which simulates the inertia and voltage source characteristics of traditional synchronous generators, enables friendly grid connection of new energy converters and has become a key technology for large-scale new energy applications. This paper addresses two key issues in low-voltage ride through (LVRT) of grid-forming converters under VSG control: (1) converter overcurrent suppression during LVRT; (2) reduced reactive power support due to retaining voltage-reactive power droop control during faults. It proposes an adaptive virtual impedance-based overcurrent suppression method and a frozen reactive power–voltage droop-based reactive support method. Based on the converter’s mathematical model, a DIgSILENT/PowerFactory simulation model is built. Time-domain simulations verify the converter’s operating characteristics and the improved LVRT strategy’s effect, providing theoretical and technical support for large-scale applications of grid-forming converters.

Zitieren

APA

Li, C., Dong, Z., Zhang, S., Mu, L., Liu, J., Liu, J., & Kai, Q. (2025). Adaptive Virtual Impedance Fault Overcurrent Suppression Method and Reactive Power Support Method with Frozen Reactive Power–Voltage Droop Control for Grid-Forming Converters. Processes, 14(1), 9. https://doi.org/10.3390/pr14010009

Vancouver

Li C, Dong Z, Zhang S, Mu L, Liu J, Liu J, et al. Adaptive Virtual Impedance Fault Overcurrent Suppression Method and Reactive Power Support Method with Frozen Reactive Power–Voltage Droop Control for Grid-Forming Converters. Processes. 2025;14(1):9. doi:10.3390/pr14010009

BibTeX
@article{Li2025,
  author = {Li, Chengshuai and Dong, Zirui and Zhang, Shuolin and Mu, Longfei and Liu, Jiahao and Liu, Jiafei and Kai, Qian},
  title = {Adaptive Virtual Impedance Fault Overcurrent Suppression Method and Reactive Power Support Method with Frozen Reactive Power–Voltage Droop Control for Grid-Forming Converters},
  journal = {Processes},
  year = {2025},
  volume = {14},
  number = {1},
  pages = {9},
  doi = {10.3390/pr14010009}
}
Kostenlos starten →