Fractional-Order Reactive Power Control for Electro-Thermal-Constrained Fault Ride-Through of Grid-Forming Converters
Fractal and Fractional · 26.07.2026 · 10 (8) · 505
DOI: 10.3390/fractalfract10080505 ↗Kurz gefasst
Fachartikel in der Zeitschrift Fractal and Fractional, online erschienen am 26.07.2026. Verfasst von Ye Tao und 8 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation.
Abstract (Originalsprache)
Grid-forming converters are essential for low-inertia power systems. However, their semiconductor current and junction-temperature limits make them vulnerable to protection-triggered blocking and thermal overstress during severe voltage sags. Existing control methods still struggle to suppress fault-instant current surges and the associated transient thermal stress induced by rapid overcurrent, which restricts the continuous operation of grid-forming converters during fault ride-through. This paper proposes a two-stage coordinated electro-thermal control strategy centered on fractional-order reactive power regulation. First, a fractional-order operator is embedded into the reactive-power loop of the virtual synchronous generator to smooth the transient response of the internal electromotive force and directly suppress the amplitude of fault-induced inrush current. By introducing a continuously tunable order, the proposed controller enhances transient damping, mitigates the waterbed effect trade-off associated with integer-order control, and reduces the initial junction-temperature shock at the fault instant. A constraint-based feasible-region identification procedure is then developed, in which a full-range parameter sweep is performed to screen fractional orders under stability, current, and thermal constraints. Second, generalized discontinuous pulse-width modulation and switching-frequency reduction are jointly applied to mitigate post-transient thermal accumulation. Electro-thermal co-simulation results indicate that, under the specified voltage-sag condition, the proposed strategy reduces transient overcurrent and thermal stress and improves the simulated fault-ride-through performance of grid-forming converters without additional hardware thermal margins.
Förderung
- National Natural Science Foundation of China
- China Postdoctoral Science Foundation
Zitieren
APA
Tao, Y., Lu, T., Yu, Y., Xiang, Y., Ying, H., Li, F., Qiao, S., Huang, Z., & Yu, Y. (2026). Fractional-Order Reactive Power Control for Electro-Thermal-Constrained Fault Ride-Through of Grid-Forming Converters. Fractal and Fractional, 10(8), 505. https://doi.org/10.3390/fractalfract10080505
Vancouver
Tao Y, Lu T, Yu Y, Xiang Y, Ying H, Li F, et al. Fractional-Order Reactive Power Control for Electro-Thermal-Constrained Fault Ride-Through of Grid-Forming Converters. Fractal and Fractional. 2026;10(8):505. doi:10.3390/fractalfract10080505
BibTeX
@article{Tao2026,
author = {Tao, Ye and Lu, Tao and Yu, Yue and Xiang, Yanming and Ying, Haizhou and Li, Fan and Qiao, Shenghua and Huang, Zhenshan and Yu, Yaci},
title = {Fractional-Order Reactive Power Control for Electro-Thermal-Constrained Fault Ride-Through of Grid-Forming Converters},
journal = {Fractal and Fractional},
year = {2026},
volume = {10},
number = {8},
pages = {505},
doi = {10.3390/fractalfract10080505}
}
EUVIMED