Thermal Performance Evaluation for Two Designs of Flat-Plate Solar Air Heater: An Experimental and CFD Investigations
Processes · 16.04.2023 · 11 (4) · 1227
DOI: 10.3390/pr11041227 ↗Kurz gefasst
Fachartikel in der Zeitschrift Processes, online erschienen am 16.04.2023. Verfasst von Mahmoud S. El-Sebaey und 3 weiteren Autor:innen. Die Arbeit wurde bisher 58-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The main objective of this research was to create two different configurations of a flat-plate solar air heater, namely, Conventional-Case A and Modified-Case B, and develop a three-dimensional computational fluid dynamics (CFD) model using ANSYS R15.0. The purpose of the CFD model was to simulate the heat transfer behavior of the proposed solar air heaters under unsteady conditions. The RNG k-ε turbulence model was employed for this CFD study. The experiments were conducted on sunny days, under the same conditions as the Egyptian climate. The results of the experiments show that the simulated CFD model and the measured outlet airflow temperatures, relative humidity, and velocities of the two tested solar air heaters were compared. The developed model made very satisfactory predictions. Moreover, the deviations between the average CFD outlet air temperatures and the experimental results were 7% and 7.8% for Case B and Case A, respectively. The CFD-simulated average relative humidity was reduced by 31.6% when using Case B compared with Case A, and it was reduced by 28.8% when comparing the experimental data to Case B. Additionally, the average CFD thermal efficiencies obtained for Case B and Case A were 28.7% and 21.6%, respectively, while the average experimental thermal efficiencies for the cases were 26.4% and 18.2%, respectively. The proposed model can be used to design and simulate other solar air heater designs.
Zitieren
APA
El-Sebaey, M. S., Ellman, A., El-Din, S. S., & Essa, F. A. (2023). Thermal Performance Evaluation for Two Designs of Flat-Plate Solar Air Heater: An Experimental and CFD Investigations. Processes, 11(4), 1227. https://doi.org/10.3390/pr11041227
Vancouver
El-Sebaey MS, Ellman A, El-Din SS, Essa FA. Thermal Performance Evaluation for Two Designs of Flat-Plate Solar Air Heater: An Experimental and CFD Investigations. Processes. 2023;11(4):1227. doi:10.3390/pr11041227
BibTeX
@article{ElSebaey2023,
author = {El-Sebaey, Mahmoud S. and Ellman, Asko and El-Din, Sh. Shams and Essa, Fadl A.},
title = {Thermal Performance Evaluation for Two Designs of Flat-Plate Solar Air Heater: An Experimental and CFD Investigations},
journal = {Processes},
year = {2023},
volume = {11},
number = {4},
pages = {1227},
doi = {10.3390/pr11041227}
}