EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Hydrogen Compatibility of Commercial Silicone Elastomer Seals: Multiscale Mechanical and Surface Characterization Following High-Pressure Hydrogen Exposure

Nitesh Subedi iD, Alfredo Becerril Corral, Md Ariful Islam, Md Monjur Hossain Bhuiyan iD, Zahed Siddique iD

Polymers · 03.11.2026 · 18 (21) · 2733

DOI: 10.3390/polym18212733 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polymers, online erschienen am 03.11.2026. Verfasst von Nitesh Subedi und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Commercial silicone O-rings were exposed to hydrogen pressures up to 7000 psi for 192 h and evaluated using mechanical, data-driven, and microstructural characterization. ASTM D1414-based O-ring tensile testing was complemented by multivariate and functional analyses, while surface evolution was quantified using SEM-based image analysis and spatial statistics. Inclusion of an unexposed 0 psi mechanical control revealed a non-monotonic exposure-associated response. Several hydrogen-exposed groups exhibited greater ultimate elongation, tensile toughness, and structural loading work than the unexposed control, whereas these quantities decreased at 7000 psi relative to selected lower-pressure exposed groups. Welch ANOVA identified significant overall group effects for tensile strength, ultimate elongation, toughness, and structural loading work. The normalized tensile-curve shapes and several stiffness-related descriptors showed smaller relative differences than the failure-related properties. These results demonstrate that hydrogen exposure was associated with changes in deformability and failure response, but the tensile data alone do not establish the molecular mechanism responsible for these changes. Quantitative SEM analysis revealed pressure-associated differences in localized morphology and spatial organization, including a tendency toward reduced dark-feature number density and variation in the magnitude and length scale of feature clustering among the analyzed conditions, without evidence of catastrophic surface degradation in the examined SEM fields. Overall, the investigated silicone exhibited non-monotonic exposure-associated changes in mechanical response together with localized pressure-associated surface evolution, without evidence of catastrophic surface degradation in the analyzed SEM fields. These findings provide comparative post-exposure material-response data for commercial silicone O-rings under high-pressure hydrogen conditions.

Schlagwörter

Stichwörter der Autor:innen

elastomeric sealshigh-pressure hydrogenhydrogen compatibilitymechanical characterizationquantitative SEM image analysissilicone elastomer

Autor:innen und Institutionen

  • School of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA.

ORCID-Profile: Nitesh Subedi, Md Monjur Hossain Bhuiyan, Zahed Siddique

Zitieren

APA

Subedi, N., Becerril Corral, A., Islam, M. A., Bhuiyan, M. M. H., & Siddique, Z. (2026). Hydrogen Compatibility of Commercial Silicone Elastomer Seals: Multiscale Mechanical and Surface Characterization Following High-Pressure Hydrogen Exposure. Polymers, 18(21), 2733. https://doi.org/10.3390/polym18212733

Vancouver

Subedi N, Becerril Corral A, Islam MA, Bhuiyan MMH, Siddique Z. Hydrogen Compatibility of Commercial Silicone Elastomer Seals: Multiscale Mechanical and Surface Characterization Following High-Pressure Hydrogen Exposure. Polymers. 2026;18(21):2733. doi:10.3390/polym18212733

BibTeX
@article{Subedi2026,
  author = {Subedi, Nitesh and Becerril Corral, Alfredo and Islam, Md Ariful and Bhuiyan, Md Monjur Hossain and Siddique, Zahed},
  title = {Hydrogen Compatibility of Commercial Silicone Elastomer Seals: Multiscale Mechanical and Surface Characterization Following High-Pressure Hydrogen Exposure},
  journal = {Polymers},
  year = {2026},
  volume = {18},
  number = {21},
  pages = {2733},
  doi = {10.3390/polym18212733}
}
Kostenlos starten →