Journal article in Polymers, published online on 2026-05-09. Written by Eylul Kosoglu and 2 co-authors. Institution: Chemical Engineering Department, Faculty of Engineering, Marmara University, Maltepe, Istanbul 34854, Türkiye. 69 references. The full text is freely available (open access, CC BY 4.0). Funded by: TUBITAK, Marmara University Scientific Projects Committee, Scientific and Technological Research Council of Türkiye.
Abstract (original language)
Hydrothermally treated chitosan/polyvinyl alcohol beads (H-CS/PVA) were used as filler material in a fixed-bed column for continuous Cr (VI) removal. The effects of main operational parameters, namely bed height, initial concentration and flow rate, were evaluated in the respective ranges of 2–6 cm, 20–60 mg/L and 2.5–7.5 mL/min. Maximum removal efficiency and adsorption capacity were calculated as 64.2% and 15.53 mg/g, respectively. The corresponding breakthrough curves were analyzed by Yoon–Nelson, Adams–Bohart, Thomas and BDST (Bed Depth–Service Time) models, out of which the highest consistency was achieved with the Yoon–Nelson model for all studied conditions. The adsorbent maintained strong reusability, showing minimal loss (~2.5%) in desorption efficiency across three successive regeneration cycles with 0.1 M NaOH as the eluent. SEM and SEM–EDX analyses confirmed the presence of chromium on the H-CS/PVA surface at an elemental fraction of 1.03% (w.). Furthermore, FTIR and XPS analyses verified the role of amine and hydroxyl functionalities in the complexation and adsorption of Cr (VI). Overall, a column system operated under optimal conditions (Hbed: 6 cm, C0: 40 mg/L, and column diameter: 2.5 cm) and regenerated three times can efficiently treat 20 L of Cr (VI)-contaminated wastewater, resulting in an associated environmental impact of 0.896 kg CO2-eq.
Subjects
Author keywords
Authors and institutions
- Chemical Engineering Department, Faculty of Engineering, Marmara University, Maltepe, Istanbul 34854, Türkiye.
ORCID profiles: Yasar Andelib Aydin
Funding
- TUBITAK
- Marmara University Scientific Projects Committee
- Scientific and Technological Research Council of Türkiye
Cite
APA
Kosoglu, E., Demirci Ulke, A. S., & Aydin, Y. A. (2026). Adsorptive Treatment of Cr (VI)-Contaminated Wastewater in a Fixed-Bed Column Using Hydrothermal Chitosan/Polyvinyl Alcohol Beads and Life Cycle Assessment. Polymers, 18(10), 1167. https://doi.org/10.3390/polym18101167
Vancouver
Kosoglu E, Demirci Ulke AS, Aydin YA. Adsorptive Treatment of Cr (VI)-Contaminated Wastewater in a Fixed-Bed Column Using Hydrothermal Chitosan/Polyvinyl Alcohol Beads and Life Cycle Assessment. Polymers. 2026;18(10):1167. doi:10.3390/polym18101167
BibTeX
@article{Kosoglu2026,
author = {Kosoglu, Eylul and Demirci Ulke, Asude Sena and Aydin, Yasar Andelib},
title = {Adsorptive Treatment of Cr (VI)-Contaminated Wastewater in a Fixed-Bed Column Using Hydrothermal Chitosan/Polyvinyl Alcohol Beads and Life Cycle Assessment},
journal = {Polymers},
year = {2026},
volume = {18},
number = {10},
pages = {1167},
doi = {10.3390/polym18101167}
}
EUVIMED