Effect of Thermal Processing on Surface Roughness of Injection-Molded Denture Base Polymers
Polymers · 22.04.2026 · 18 (9) · 1010
DOI: 10.3390/polym18091010 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polymers, online erschienen am 22.04.2026. Verfasst von Bozhana Chuchulska und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Regional Development Fund.
Abstract (Originalsprache)
Surface roughness and mechanical performance are critical determinants of the clinical behavior, hygiene, and longevity of denture base materials. This study investigated the influence of two extrusion temperatures—280 °C and 300 °C—on both the surface roughness and compressive strength of ThermoSens thermoplastic polymer specimens over a 7-day immersion period. Surface roughness was evaluated at baseline, 24 h, and 7 days using a contact profilometer, while compressive strength was measured after 7 days following ISO 604 guidelines. Samples processed at 300 °C exhibited a significantly greater reduction in surface roughness over time (28.3%) compared with those processed at 280 °C (18.3%). However, although specimens processed at 300 °C showed a greater percentage reduction, their absolute roughness values remained higher than those processed at 280 °C. Compression testing demonstrated higher strength and modulus values in the 300 °C group (91.6 ± 1.8 MPa; 1887.9 ± 42.3 MPa) compared to the 280 °C group (82.3 ± 2.1 MPa; 1755.4 ± 38.7 MPa). These findings indicate a trade-off between improved mechanical performance at higher processing temperatures and lower surface roughness at lower temperatures, highlighting the need for the careful optimization of processing conditions.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria.
- Department of Mechanics, Faculty of Mechanical Engineering, Technical University of Sofia, Branch Plovdiv, 4000 Plovdiv, Bulgaria.
- Center of Competence "Smart Mechatronic, Eco-and Energy-Saving Systems and Technologies", 4000 Plovdiv, Bulgaria.
- Department of Mechanical and Instrument Engineering, Faculty of Mechanical Engineering, Technical University of Sofia, Branch Plovdiv, 4000 Plovdiv, Bulgaria.
ORCID-Profile: Bozhana Chuchulska, Mariya Dimitrova, Boyan Dochev, Kliment Georgiev
Förderung
- European Regional Development Fund
Zitieren
APA
Chuchulska, B., Dimitrova, M., Dochev, B., & Georgiev, K. (2026). Effect of Thermal Processing on Surface Roughness of Injection-Molded Denture Base Polymers. Polymers, 18(9), 1010. https://doi.org/10.3390/polym18091010
Vancouver
Chuchulska B, Dimitrova M, Dochev B, Georgiev K. Effect of Thermal Processing on Surface Roughness of Injection-Molded Denture Base Polymers. Polymers. 2026;18(9):1010. doi:10.3390/polym18091010
BibTeX
@article{Chuchulska2026,
author = {Chuchulska, Bozhana and Dimitrova, Mariya and Dochev, Boyan and Georgiev, Kliment},
title = {Effect of Thermal Processing on Surface Roughness of Injection-Molded Denture Base Polymers},
journal = {Polymers},
year = {2026},
volume = {18},
number = {9},
pages = {1010},
doi = {10.3390/polym18091010}
}
EUVIMED