Microwave Resonant Probe-Based Defect Detection for Butt Fusion Joints in High-Density Polyethylene Pipes
Polymers · 27.09.2025 · 17 (19) · 2617
DOI: 10.3390/polym17192617 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polymers, online erschienen am 27.09.2025. Verfasst von Jinping Pan und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical and Electrical Engineering, China University of Mining and Technology, Xuzhou 221116, China. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Chu Ying Plan Program of Zhejiang Provincial Bureau of Market Supervision.
Abstract (Originalsprache)
With the widespread use of high-density polyethylene (HDPE) pipes in various industrial and municipal applications, ensuring the structural integrity of their joints is crucial. This paper presents a novel defect detection method based on a microwave resonant probe, designed to perform efficient and non-destructive evaluation of butt fusion joints in HDPE pipes. The experimental setup integrates a microwave antenna and resonant cavity to record real-time variations in resonance frequency and S21 magnitude while scanning the pipe surface. This method effectively detects common defects, including cracks, holes, and inclusions, within the butt fusion joints. The results show that the microwave resonant probe exhibits high sensitivity in detecting HDPE pipe defects. It can identify different sizes of cracks and holes, and can distinguish between talc powder and sand particles. This technique offers a promising solution for pipeline health monitoring, particularly for evaluating the quality of welded joints in non-metallic materials.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Mechanical and Electrical Engineering, China University of Mining and Technology, Xuzhou 221116, China.
- Jiaxing Special Equipment Inspection and Testing Institute, Jiaxing 314000, China.
- School of Materials Science and Engineering, Shanghai Institute of Technology, Shanghai 201418, China.
Förderung
- Chu Ying Plan Program of Zhejiang Provincial Bureau of Market Supervision
Zitieren
APA
Pan, J., Zhu, C., & Tan, L. (2025). Microwave Resonant Probe-Based Defect Detection for Butt Fusion Joints in High-Density Polyethylene Pipes. Polymers, 17(19), 2617. https://doi.org/10.3390/polym17192617
Vancouver
Pan J, Zhu C, Tan L. Microwave Resonant Probe-Based Defect Detection for Butt Fusion Joints in High-Density Polyethylene Pipes. Polymers. 2025;17(19):2617. doi:10.3390/polym17192617
BibTeX
@article{Pan2025,
author = {Pan, Jinping and Zhu, Chaoming and Tan, Lianjiang},
title = {Microwave Resonant Probe-Based Defect Detection for Butt Fusion Joints in High-Density Polyethylene Pipes},
journal = {Polymers},
year = {2025},
volume = {17},
number = {19},
pages = {2617},
doi = {10.3390/polym17192617}
}
EUVIMED