Does the Addition of Low-Dose Antibiotics Compromise the Mechanical Properties of Polymethylmethacrylate (PMMA)?
Polymers · 22.08.2024 · 16 (16) · 2378
DOI: 10.3390/polym16162378 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polymers, online erschienen am 22.08.2024. Verfasst von Valentina Egger und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic and Traumatology, Medical University of Innsbruck, 6020 Innsbruck, Austria. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The increasing numbers of total joint replacements and related implant-associated infections demand solutions, which can provide a high-dose local delivery of antibiotics. Antibiotic-loaded bone cement (ALBC) is an accepted treatment method for infected joint arthroplasties. The mechanical properties of low-dose gentamicin-loaded bone cement (BC) in medium- and high-viscosity versions were compared to unloaded BC using a vacuum mixing system. As an additional control group, manual mixed unloaded BC was used. In a uniaxial compression test, ultimate compressive strength, compressive yield strength, and compression modulus of elasticity, as well as ultimate and yield strain, were determined according to ISO 5833-2022 guidelines. All groups exceeded the minimum compressive strength (70 MPa) specified in the ISO 5833 guidelines. Both ALBC groups showed a similar ultimate compressive and yield strength to the unloaded BC. The results showed that vacuum mixing increased the compression strength of BC. ALBC showed similar compressive strength to their non-antibiotic counterparts when vacuum mixing was performed. Added low-dose gentamicin acted as a plasticizer on bone cement. From a biomechanical point of view, the usage of gentamicin-based ALBC formulations is viable.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic and Traumatology, Medical University of Innsbruck, 6020 Innsbruck, Austria.
- Department for Orthopaedics and Traumatology, University Hospital Krems, 3500 Krems an der Donau, Austria.
- Department for Orthopedics and Traumatology, Karl Landsteiner University of Health Sciences, 3500 Krems an der Donau, Austria.
- Department for Radiology, Medical University of Innsbruck, 6020 Innsbruck, Austria.
- Helios Klinikum, Arthroplasty Center Munich West, 81241 Munich, Germany.
- Center of Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University of Greifswald, 17489 Greifswald, Germany.
ORCID-Profile: Valentina Egger, Dietmar Dammerer, Gerald Degenhart, Johannes D Pallua, Werner Schmölz, David Putzer
Zitieren
APA
Egger, V., Dammerer, D., Degenhart, G., Pallua, J. D., Schmölz, W., Thaler, M., Kühn, K. D., Nogler, M., & Putzer, D. (2024). Does the Addition of Low-Dose Antibiotics Compromise the Mechanical Properties of Polymethylmethacrylate (PMMA)?. Polymers, 16(16), 2378. https://doi.org/10.3390/polym16162378
Vancouver
Egger V, Dammerer D, Degenhart G, Pallua JD, Schmölz W, Thaler M, et al. Does the Addition of Low-Dose Antibiotics Compromise the Mechanical Properties of Polymethylmethacrylate (PMMA)?. Polymers. 2024;16(16):2378. doi:10.3390/polym16162378
BibTeX
@article{Egger2024,
author = {Egger, Valentina and Dammerer, Dietmar and Degenhart, Gerald and Pallua, Johannes D and Schmölz, Werner and Thaler, Martin and Kühn, Klaus-Dieter and Nogler, Michael and Putzer, David},
title = {Does the Addition of Low-Dose Antibiotics Compromise the Mechanical Properties of Polymethylmethacrylate (PMMA)?},
journal = {Polymers},
year = {2024},
volume = {16},
number = {16},
pages = {2378},
doi = {10.3390/polym16162378}
}
EUVIMED