EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Conventional Dental Impressions vs. Impressions Reinforced with Rigid Mouthguards

Andreea Codruta Novac, Anca Tudor iD, Daniela Maria Pop, Carina Sonia Neagu iD, Emanuela Lidia Crăciunescu iD, Mihai Romînu iD, Meda Lavinia Negruțiu iD, Virgil-Florin Duma iD, Cosmin Sinescu iD

Polymers · 04.04.2024 · 16 (7) · 994

DOI: 10.3390/polym16070994 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polymers, online erschienen am 04.04.2024. Verfasst von Andreea Codruta Novac und 8 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Dental Medicine, "Victor Babes" University of Medicine and Pharmacy of Timisoara, 2 Eftimie Murgu Square, 300041 Timisoara, Romania. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Romanian Ministry of Research, Innovation and Digitization, CNCS/CCCDI-UEFISCDI, European Commission, “Victor Babes” University of Medicine and Pharmacy of Timisoara.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The impression materials utilized today in dental medicine offer a good reproducibility and are easily accepted by patients. However, because they are polymer-based, they have issues regarding their dimensional stability. In this respect, the present work proposes a new type of dental impression, which is reinforced with rigid mouthguards. The aim of the study is to test the performances of such new impressions by comparing them to conventional ones—from this critical point of view, of the dimensional stability. Three types of polymeric materials were considered for both types of impressions: alginate, condensation silicone, and addition silicone. In order to obtain the new type of impressions, a manufacturing technique was developed, comprising the following phases: (i) conventional impressions were made; (ii) a plaster model was duplicated, and 15 rigid mouthguards were obtained; (iii) they were inserted in the impression technique, with each mouthguard positioned on the cast before the high-consistency material was inserted in the tray and the practitioner took the impression; (iv) the mouthguard remained in the tray and the low-viscosity material was inserted over the mouthguard; (v) the impression was positioned on the model, and after the material hardened, the mouthguard-reinforced impression was analyzed. In the evaluation of the dimensional stability, rigorous statistical analysis was essential to discern the performance differences between conventional and mouthguard-reinforced dental impressions. Statistical analyses employed non-parametric Mann–Whitney U tests because of the non-normal distribution of the data. They indicated a statistically significant improvement in the dimensional stability of addition silicone impressions when reinforced with mouthguards (p < 0.05), showcasing superior performance over conventional methods. Conversely, alginate and condensation silicone reinforced impressions did not exhibit the same level of stability improvement, suggesting the need for further optimization of these materials. In conclusion, from the three considered elastomers, addition silicone was found to be the prime candidate for high-precision dental impressions, with the potential to improve their quality from conventional impressions by utilizing the proposed reinforcing technique.

Schlagwörter

Stichwörter der Autor:innen

addition siliconealginatecondensation siliconedental impressionsdimensional stabilitymouthguardpolymeric materialsreinforced dental impressions

Autor:innen und Institutionen

  • Faculty of Dental Medicine, "Victor Babes" University of Medicine and Pharmacy of Timisoara, 2 Eftimie Murgu Square, 300041 Timisoara, Romania.
  • Research Center in Dental Medicine Using Conventional and Alternative Technologies, Department of Prostheses Technology and Dental Materials, Faculty of Dental Medicine, "Victor Babes" University of Medicine and Pharmac…
  • 3OM Optomechatronics Group, Faculty of Engineering, "Aurel Vlaicu" University of Arad, 2 Elena Dragoi Str., 310177 Arad, Romania.
  • Faculty of Electronics, Telecommunications, and Information Technology, Polytechnic University of Timisoara, 2 Vasile Parvan Ave., 300223 Timisoara, Romania.
  • Center of Research and Development for Mechatronics, National University of Science and Technology POLITEHNICA Bucharest, Splaiul Independentei 313, Sector 6, 060042 Bucharest, Romania.

ORCID-Profile: Anca Tudor, Carina Sonia Neagu, Emanuela Lidia Crăciunescu, Mihai Romînu, Meda Lavinia Negruțiu, Virgil-Florin Duma, Cosmin Sinescu

Förderung

  • Romanian Ministry of Research, Innovation and Digitization, CNCS/CCCDI-UEFISCDI
  • European Commission
  • “Victor Babes” University of Medicine and Pharmacy of Timisoara
  • Romanian Ministry of Research, Innovation and Digitization, CNCS/CCCDI–UEFISCDI
  • COST Action

Zitieren

APA

Novac, A. C., Tudor, A., Pop, D. M., Neagu, C. S., Crăciunescu, E. L., Romînu, M., Negruțiu, M. L., Duma, V. F., & Sinescu, C. (2024). Conventional Dental Impressions vs. Impressions Reinforced with Rigid Mouthguards. Polymers, 16(7), 994. https://doi.org/10.3390/polym16070994

Vancouver

Novac AC, Tudor A, Pop DM, Neagu CS, Crăciunescu EL, Romînu M, et al. Conventional Dental Impressions vs. Impressions Reinforced with Rigid Mouthguards. Polymers. 2024;16(7):994. doi:10.3390/polym16070994

BibTeX
@article{Novac2024,
  author = {Novac, Andreea Codruta and Tudor, Anca and Pop, Daniela Maria and Neagu, Carina Sonia and Crăciunescu, Emanuela Lidia and Romînu, Mihai and Negruțiu, Meda Lavinia and Duma, Virgil-Florin and Sinescu, Cosmin},
  title = {Conventional Dental Impressions vs. Impressions Reinforced with Rigid Mouthguards},
  journal = {Polymers},
  year = {2024},
  volume = {16},
  number = {7},
  pages = {994},
  doi = {10.3390/polym16070994}
}
Kostenlos starten →