Platinum Black/Gold Nanoparticles/Polyaniline Modified Electrochemical Microneedle Sensors for Continuous In Vivo Monitoring of pH Value
Polymers · 23.06.2023 · 15 (13) · 2796
DOI: 10.3390/polym15132796 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polymers, online erschienen am 23.06.2023. Verfasst von Tao Ming und 7 weiteren Autor:innen. Beteiligte Einrichtung: Research Institute of Transplant Medicine, Tianjin First Central Hospital, Nankai University, Tianjin 300190, China. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Major Scientific Research Instrument Development Project, the Nature Science Foundation of China, National Major Scientific Research Instrument Development Project of China.
Abstract (Originalsprache)
Continuous in vivo monitoring (CIVM) of pH value is essential for personalized medicine, as many diseases are closely related to acid–base imbalances. However, conventional pH meters are limited in their ability to perform CIVM due to excessive blood consumption, large device volume, frequent calibration, and inadequate real-time monitoring. There is thus an urgent need for a portable method for CIVM of pH value. To address this need, we propose a minimally invasive, continuous monitoring solution in the form of an implantable pH microneedle sensor (MNS) in this study. The MNS is based on the integration of an acupuncture needle (AN) and a Ag/AgCl reference electrode. We fabricate the sensor by electrochemically depositing platinum black and gold nanoparticles onto the AN and further modifying it with polyaniline to increase its sensitivity to hydrogen ions. The pH value is obtained by calculating the open circuit voltage between the modified AN and the reference electrode. The resulting MNS demonstrates excellent selectivity and a high nernstian response to pH (−57.4 mV per pH) over a broad range (pH = 4.0 to pH = 9.0). Both in vitro and in vivo experiments have verified the performance of the sensor, showcasing its potential for biomedical research and clinical practice. The MNS provides an alternative to conventional pH meters, offering a less invasive and more convenient way to perform CIVM of pH value. Moreover, this electrochemical implantable sensor based on AN and silver wires provides a simple and sensitive method for continuous in vivo detection of other biomarkers.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research Institute of Transplant Medicine, Tianjin First Central Hospital, Nankai University, Tianjin 300190, China.
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China.
ORCID-Profile: Tao Ming, Mingxing Yu
Förderung
- the National Major Scientific Research Instrument Development Project
- the Nature Science Foundation of China
- National Major Scientific Research Instrument Development Project of China
- Fundamental Research Funds for the Central Universities, Nankai University
- Nature Science Foundation of China
Zitieren
APA
Ming, T., Lan, T., Yu, M., Wang, H., Deng, J., Kong, D., Yang, S., & Shen, Z. (2023). Platinum Black/Gold Nanoparticles/Polyaniline Modified Electrochemical Microneedle Sensors for Continuous In Vivo Monitoring of pH Value. Polymers, 15(13), 2796. https://doi.org/10.3390/polym15132796
Vancouver
Ming T, Lan T, Yu M, Wang H, Deng J, Kong D, et al. Platinum Black/Gold Nanoparticles/Polyaniline Modified Electrochemical Microneedle Sensors for Continuous In Vivo Monitoring of pH Value. Polymers. 2023;15(13):2796. doi:10.3390/polym15132796
BibTeX
@article{Ming2023,
author = {Ming, Tao and Lan, Tingting and Yu, Mingxing and Wang, Hong and Deng, Juan and Kong, Deling and Yang, Shuang and Shen, Zhongyang},
title = {Platinum Black/Gold Nanoparticles/Polyaniline Modified Electrochemical Microneedle Sensors for Continuous In Vivo Monitoring of pH Value},
journal = {Polymers},
year = {2023},
volume = {15},
number = {13},
pages = {2796},
doi = {10.3390/polym15132796}
}
EUVIMED