EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Label-Free Electrochemical Biosensor for Homocysteine Detection Using Molecularly Imprinted Polymer and Nanocomposite-Modified Electrodes

Unchalee Kongintr, Benchaporn Lertanantawong iD, Chamras Promptmas iD

Polymers · 09.05.2023 · 15 (10) · 2241

DOI: 10.3390/polym15102241 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polymers, online erschienen am 09.05.2023. Verfasst von Unchalee Kongintr und 2 weiteren Autor:innen. Beteiligte Einrichtung: Biosensor Laboratory, Department of Biomedical Engineering, Faculty of Engineering, Mahidol University, Nakhon Pathom 73170, Thailand. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Development Agency (NSTDA), Thailand.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An essential biomarker for the early detection of cardiovascular diseases is serum homocysteine (Hcy). In this study, a molecularly imprinted polymer (MIP) and nanocomposite were used to create a label-free electrochemical biosensor for reliable Hcy detection. A novel Hcy-specific MIP (Hcy-MIP) was synthesized using methacrylic acid (MAA) in the presence of trimethylolpropane trimethacrylate (TRIM). The Hcy-MIP biosensor was fabricated by overlaying the mixture of Hcy-MIP and the carbon nanotube/chitosan/ionic liquid compound (CNT/CS/IL) nanocomposite on the surface of a screen-printed carbon electrode (SPCE). It showed high sensitivity, with a linear response of 5.0 to 150 µM (R2 of 0.9753) and with a limit of detection (LOD) at 1.2 µM. It demonstrated low cross-reactivity with ascorbic acid, cysteine, and methionine. Recoveries of 91.10–95.83% were achieved when the Hcy-MIP biosensor was used for Hcy at 50–150 µM concentrations. The repeatability and reproducibility of the biosensor at the Hcy concentrations of 5.0 and 150 µM were very good, with coefficients of variation at 2.27–3.50% and 3.42–4.22%, respectively. This novel biosensor offers a new and effective method for Hcy assay compared with the chemiluminescent microparticle immunoassay at the correlation coefficient (R2) of 0.9946.

Schlagwörter

Stichwörter der Autor:innen

biosensorcarbon nanotubeelectrochemical biosensorhomocysteinemolecularly imprinted polymernanocomposite

Autor:innen und Institutionen

  • Biosensor Laboratory, Department of Biomedical Engineering, Faculty of Engineering, Mahidol University, Nakhon Pathom 73170, Thailand.
  • Faculty of Medical Technology, Huachiew Chalermprakiat University, Samut Prakan 10540, Thailand.

ORCID-Profile: Benchaporn Lertanantawong, Chamras Promptmas

Förderung

  • National Science and Technology Development Agency (NSTDA), Thailand

Zitieren

APA

Kongintr, U., Lertanantawong, B., & Promptmas, C. (2023). A Label-Free Electrochemical Biosensor for Homocysteine Detection Using Molecularly Imprinted Polymer and Nanocomposite-Modified Electrodes. Polymers, 15(10), 2241. https://doi.org/10.3390/polym15102241

Vancouver

Kongintr U, Lertanantawong B, Promptmas C. A Label-Free Electrochemical Biosensor for Homocysteine Detection Using Molecularly Imprinted Polymer and Nanocomposite-Modified Electrodes. Polymers. 2023;15(10):2241. doi:10.3390/polym15102241

BibTeX
@article{Kongintr2023,
  author = {Kongintr, Unchalee and Lertanantawong, Benchaporn and Promptmas, Chamras},
  title = {A Label-Free Electrochemical Biosensor for Homocysteine Detection Using Molecularly Imprinted Polymer and Nanocomposite-Modified Electrodes},
  journal = {Polymers},
  year = {2023},
  volume = {15},
  number = {10},
  pages = {2241},
  doi = {10.3390/polym15102241}
}
Kostenlos starten →