EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Study of Prepared Lead-Free Polymer Nanocomposites for X- and Gamma-ray Shielding in Healthcare Applications

Abdulrhman Hasan Alsaab, Sadek Zeghib iD

Polymers · 29.04.2023 · 15 (9) · 2142

DOI: 10.3390/polym15092142 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polymers, online erschienen am 29.04.2023. Verfasst von Abdulrhman Hasan Alsaab und 1 weiteren Autor:innen. Beteiligte Einrichtung: Physics Department, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia. Die Arbeit wurde bisher 53-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Polymer composites were synthesized via melt mixing for radiation shielding in the healthcare sector. A polymethyl-methacrylate (PMMA) matrix was filled with Bi2O3 nanoparticles at 10%, 20%, 30%, and 40% weight percentages. The characterization of nanocomposites included their morphological, structural, and thermal properties, achieved using SEM, XRD, and TGA, respectively. The shielding properties for all synthesized samples including pristine PMMA were measured with gamma spectrometry using a NaI (Tl) scintillator detector spanning a wide range of energies and using different radioisotopes, namely Am-241 (59.6 keV), Co-57 (122.2 keV), Ra-226 (242.0), Ba-133 (80.99 and 356.02 keV), Cs-137 (661.6 keV), and Co-60 (1173.2 and 1332.5 keV). A substantial increase in the mass attenuation coefficients was obtained at low and medium energies as the filler weight percentage increased, with minor variations at higher gamma energies (1173 and 1332 keV). The mass attenuation coefficient decreased with increasing energy except under 122 keV gamma rays due to the K-absorption edge of bismuth (90.5 keV). At 40% loading of Bi2O3, the mass attenuation coefficient for the cesium 137Cs gamma line at 662 keV reached the corresponding value for the toxic heavy element lead. The synthesized PMMA-Bi2O3 nanocomposites proved to be highly effective, lead-free, safe, and lightweight shielding materials for X- and gamma rays within a wide energy range (

Schlagwörter

Stichwörter der Autor:innen

Bi2O3attenuation of gamma rayspolymeric nanocompositeradiation shielding

Autor:innen und Institutionen

  • Physics Department, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia.

ORCID-Profile: Sadek Zeghib

Zitieren

APA

Alsaab, A. H., & Zeghib, S. (2023). Study of Prepared Lead-Free Polymer Nanocomposites for X- and Gamma-ray Shielding in Healthcare Applications. Polymers, 15(9), 2142. https://doi.org/10.3390/polym15092142

Vancouver

Alsaab AH, Zeghib S. Study of Prepared Lead-Free Polymer Nanocomposites for X- and Gamma-ray Shielding in Healthcare Applications. Polymers. 2023;15(9):2142. doi:10.3390/polym15092142

BibTeX
@article{Alsaab2023,
  author = {Alsaab, Abdulrhman Hasan and Zeghib, Sadek},
  title = {Study of Prepared Lead-Free Polymer Nanocomposites for X- and Gamma-ray Shielding in Healthcare Applications},
  journal = {Polymers},
  year = {2023},
  volume = {15},
  number = {9},
  pages = {2142},
  doi = {10.3390/polym15092142}
}
Kostenlos starten →