EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Numerical Investigation into GFRP Composite Pipes under Hydrostatic Internal Pressure

Tamer Ali Sebeay iD, Azzam Ahmed iD

Polymers · 2023-02-23 · 15 (5) · 1110

DOI: 10.3390/polym15051110 ↗

At a glance

Journal article in Polymers, published online on 2023-02-23. Written by Tamer Ali Sebeay and 1 co-authors. Institution: Engineering Management Department, College of Engineering, Prince Sultan University, Riyadh 11586, Saudi Arabia. Cited 30 times so far (Crossref); 60 references. The full text is freely available (open access, CC BY 4.0). Funded by: Prince Sultan University.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Glass-fiber-reinforced plastic (GFRP) composite pipes are used extensively in high-performance applications, due to their high stiffness and strength, corrosion resistance, and thermal and chemical stability. In piping, composites showed high performance due to their long service life. In this study, glass-fiber-reinforced plastic composite pipes with [±40]3, [±45]3, [±50]3, [±55]3, [±60]3, [±65]3, and [±70]3 fiber angles and varied pipe wall thicknesses (3.78–5.1 mm) and lengths (110–660 mm) were subjected to constant hydrostatic internal pressure to obtain the pressure resistance capacity of the glass-fiber-reinforced plastic composite pipe, hoop and axial stress, longitudinal and transverse stress, total deformation, and failure modes. For model validation, the simulation of internal pressure on a composite pipe installed on the seabed was investigated and compared with previously published data. Damage analysis based on progressive damage in the finite element model was built based on Hashin damage for the composite. Shell elements were used for internal hydrostatic pressure, due to their convenience for pressure type and property predictions. The finite element results observed that the winding angles from [±40]3 to [±55]3 and pipe thickness play a vital role in improving the pressure capacity of the composite pipe. The average total deformation of all designed composite pipes was 0.37 mm. The highest pressure capacity was observed at [±55°]3 due to the diameter-to-thickness ratio effect.

Subjects

Author keywords

GFRP pipedeformationfailure modesfinite element analysishydrostatic internal pressurewinding angles

Authors and institutions

  • Engineering Management Department, College of Engineering, Prince Sultan University, Riyadh 11586, Saudi Arabia.
  • Mechanical Design and Production Department, Faculty of Engineering, Zagazig University, Zagazig, Sharkia, Egypt.
  • Department of the Textile Engineering, College of Engineering and Technology of Industries, Sudan University of Science and Technology, Khartoum, Sudan.
  • Safat College of Science and Technology, HG6V+RP2, Khartoum, Sudan.

ORCID profiles: Tamer Ali Sebeay, Azzam Ahmed

Funding

  • Prince Sultan University

Cite

APA

Sebeay, T. A., & Ahmed, A. (2023). Numerical Investigation into GFRP Composite Pipes under Hydrostatic Internal Pressure. Polymers, 15(5), 1110. https://doi.org/10.3390/polym15051110

Vancouver

Sebeay TA, Ahmed A. Numerical Investigation into GFRP Composite Pipes under Hydrostatic Internal Pressure. Polymers. 2023;15(5):1110. doi:10.3390/polym15051110

BibTeX
@article{Sebeay2023,
  author = {Sebeay, Tamer Ali and Ahmed, Azzam},
  title = {Numerical Investigation into GFRP Composite Pipes under Hydrostatic Internal Pressure},
  journal = {Polymers},
  year = {2023},
  volume = {15},
  number = {5},
  pages = {1110},
  doi = {10.3390/polym15051110}
}
Start for free →