EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Analysis and Mitigation of Pulse-Pile-Up Artifacts in Plasma Pulse-Height X-ray Spectra

Taosif. Ahsan, Charles P. S. Swanson, Chris Galea, Sangeeta P. Vinoth, Tony Qian, Tal Rubin, Samuel A. Cohen

Plasma · 02.02.2023 · 6 (1) · 58-71

DOI: 10.3390/plasma6010006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Plasma, online erschienen am 02.02.2023. Verfasst von Taosif. Ahsan und 6 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. Department of Energy, Office of Science, Office of Fusion Energy, Princeton Fusion Systems.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pulse pile-up in pulse-height energy analyzers increases when the incident rate of pulses increases relative to the inverse of the dead time per pulse of the detection system. Changes in the observed energy distributions with incident rate and detector-electronics-formed pulse shape then occur. We focus on weak high energy tails in X-ray spectra, important for measurements on partially ionized, warm (50–500 eV average electron energy), pure hydrogen plasma. A first-principles two-photon pulse-pile-up model is derived specific to trapezoidal-shaped pulses; quantitative agreement is found between the measurements and the model’s predictions. The model is then used to diagnose pulse-pile-up tail artifacts and mitigate them in relatively low count-rate spectra.

Förderung

  • U.S. Department of Energy, Office of Science, Office of Fusion Energy
  • Princeton Fusion Systems

Zitieren

APA

Ahsan, T., Swanson, C. P. S., Galea, C., Vinoth, S. P., Qian, T., Rubin, T., & Cohen, S. A. (2023). Analysis and Mitigation of Pulse-Pile-Up Artifacts in Plasma Pulse-Height X-ray Spectra. Plasma, 6(1), 58-71. https://doi.org/10.3390/plasma6010006

Vancouver

Ahsan T, Swanson CPS, Galea C, Vinoth SP, Qian T, Rubin T, et al. Analysis and Mitigation of Pulse-Pile-Up Artifacts in Plasma Pulse-Height X-ray Spectra. Plasma. 2023;6(1):58-71. doi:10.3390/plasma6010006

BibTeX
@article{Ahsan2023,
  author = {Ahsan, Taosif. and Swanson, Charles P. S. and Galea, Chris and Vinoth, Sangeeta P. and Qian, Tony and Rubin, Tal and Cohen, Samuel A.},
  title = {Analysis and Mitigation of Pulse-Pile-Up Artifacts in Plasma Pulse-Height X-ray Spectra},
  journal = {Plasma},
  year = {2023},
  volume = {6},
  number = {1},
  pages = {58--71},
  doi = {10.3390/plasma6010006}
}
Kostenlos starten →