Effect of Light-Curing Distance on Polymerization Behavior of Resin Composites: A Systematic Review and Meta-Analysis
Physchem · 16.11.2026 · 6 (4) · 70
DOI: 10.3390/physchem6040070 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Physchem, online erschienen am 16.11.2026. Verfasst von Mohammad Alabdulkareem und 6 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The distance between the light-curing unit (LCU) tip and the resin composite surface is a clinically important factor that may influence the quality of polymerization. However, the magnitude and consistency of its effects across different composite materials and curing devices remain unclear.
Objective
To systematically evaluate the effect of LCU tip-to-surface distance on the polymerization behavior of resin composites, including degree of conversion (DC), microhardness, depth of cure, and flexural strength.
Methods
A systematic search of PubMed/MEDLINE, Scopus, Web of Science, Embase, and Google Scholar was conducted from database inception to August 2026. In vitro studies that investigated at least two curing distances and reported quantitative polymerization outcomes were included. Methodological quality was assessed using a modified reporting checklist for in vitro dental materials research (not a validated risk-of-bias instrument). Findings were synthesized narratively according to the SWiM framework, with exploratory random-effects meta-analyses performed where data permitted.
Results
Sixteen in vitro studies met the inclusion criteria. The narrative synthesis indicated that there was a tendency towards an association of increasing curing distance with decreased degree of conversion (DC), hardness, flexural strength, and depth of cure. However, the size of the effect depended on material, light-curing unit, irradiance, and exposure time. In exploratory random effects meta-analyses, which were based on two to four studies, an increase in distance was associated with lower values in comparison to direct curing at 0 mm, with all estimates in the same direction: DC was lower by 12.26 percentage points (95% confidence interval [CI], 8.07–16.45; eight comparisons from four studies), hardness was lower (standard mean difference [SMD] = 1.18; 95% CI, 0.17–2.18; seven comparisons from three studies), Knoop hardness was lower (mean difference [MD] = −5.34; 95% CI, −8.69 to −1.98; two studies), flexural strength was lower by 12.18 MPa (95% CI, −21.86 to −2.50; three studies), and depth of cure was lower by 0.54 mm (95% CI, 0.36–0.73; two studies). Heterogeneity was considerable to very high (I2 = 71.7–99.7%); 95% prediction intervals for DC, hardness, flexural strength, and depth of cure included zero, and estimates for hardness and flexural strength were not statistically significant with the Hartung–Knapp adjustment. In a single study (not pooled), bulk-fill composites demonstrated higher DC than a conventional composite at 0 mm, whereas the conventional composite showed slightly higher DC than the bulk-fill composites at 4 mm. DC was higher at the top than the bottom surface at 0 mm in three out of three studies that reported both values. These pooled estimates should be considered exploratory. Considerable heterogeneity was identified across pooled analyses.
Conclusions
In these in vitro studies, a greater distance between the LCU tip and the composite surface was generally associated with lower polymerization-related properties of resin composites, with differences most often reported from about 4 mm in the experimental settings tested; this is an experimental observation rather than a validated clinical threshold, and the maximum distance investigated was 9 mm. These exploratory findings are compatible with minimizing unnecessary curing distance, but their clinical relevance has not been established. Further research, including clinical studies, should determine whether compensation for curing distance and specific material/LCU combinations can overcome such differences.
Zitieren
APA
Alabdulkareem, M., Radwan, W., Abumustafa, A., Alharith, D., Alamassi, B., Sulaiman, O., & Aldalaan, K. (2026). Effect of Light-Curing Distance on Polymerization Behavior of Resin Composites: A Systematic Review and Meta-Analysis. Physchem, 6(4), 70. https://doi.org/10.3390/physchem6040070
Vancouver
Alabdulkareem M, Radwan W, Abumustafa A, Alharith D, Alamassi B, Sulaiman O, et al. Effect of Light-Curing Distance on Polymerization Behavior of Resin Composites: A Systematic Review and Meta-Analysis. Physchem. 2026;6(4):70. doi:10.3390/physchem6040070
BibTeX
@article{Alabdulkareem2026,
author = {Alabdulkareem, Mohammad and Radwan, Waseem and Abumustafa, Ammar and Alharith, Dalia and Alamassi, Basil and Sulaiman, Oubada and Aldalaan, Khaled},
title = {Effect of Light-Curing Distance on Polymerization Behavior of Resin Composites: A Systematic Review and Meta-Analysis},
journal = {Physchem},
year = {2026},
volume = {6},
number = {4},
pages = {70},
doi = {10.3390/physchem6040070}
}
EUVIMED