EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Polarization Calibration and Analysis of Solar-Induced Chlorophyll Fluorescence Wide-Swath Ultraspectral Imaging Spectrometer

Yiwei Li, Kaiqin Cao, Zongcun Zhang, Xiaowei Jia, Xuefei Feng, Lu Liu, Yinnian Liu

Photonics · 16.05.2026 · 13 (5) · 498

DOI: 10.3390/photonics13050498 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Photonics, online erschienen am 16.05.2026. Verfasst von Yiwei Li und 6 weiteren Autor:innen. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Advanced Research Project of Civil Aerospace Technologies, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Spaceborne detection of solar-induced chlorophyll fluorescence (SIF) requires extremely high radiometric accuracy, and the polarization characteristics of an ultra-wide swath spaceborne fluorescence ultraspectral camera directly affect the accuracy of SIF retrieval. This study takes an ultra-wide swath camera based on an off-axis three-mirror anastigmat telescope combined with a Littrow–Offner spectrometer as the research object. A full-field-of-view (FOV), full-spectral, pixel-by-pixel polarization testing system was established based on the Stokes–Muller formalism, achieving for the first time fine characterization and calibration of the pixel-level polarization properties of such a payload. The results show that: (1) polarization sensitivity (LPS) exhibits a strong linear positive correlation with wavelength (R2 > 0.97), with good uniformity (fluctuation < 1%) across the full ±15° FOV; (2) the polarization sensitive axis (PSA) shows a symmetric distribution across the FOV and gradually approaches 90° as the wavelength increases, with a clear deviation in the short-wavelength bands and stabilization in the mid-to-long wavelength bands; (3) through multiple sets of cross-validation and Monte Carlo statistics, the calibration accuracy reaches 0.1%, and the system uncertainty is better than 0.05%. This study can provide data support and a reference basis for high-accuracy spaceborne SIF retrieval, payload polarization correction, and optical design optimization.

Förderung

  • Advanced Research Project of Civil Aerospace Technologies
  • National Natural Science Foundation of China

Zitieren

APA

Li, Y., Cao, K., Zhang, Z., Jia, X., Feng, X., Liu, L., & Liu, Y. (2026). Polarization Calibration and Analysis of Solar-Induced Chlorophyll Fluorescence Wide-Swath Ultraspectral Imaging Spectrometer. Photonics, 13(5), 498. https://doi.org/10.3390/photonics13050498

Vancouver

Li Y, Cao K, Zhang Z, Jia X, Feng X, Liu L, et al. Polarization Calibration and Analysis of Solar-Induced Chlorophyll Fluorescence Wide-Swath Ultraspectral Imaging Spectrometer. Photonics. 2026;13(5):498. doi:10.3390/photonics13050498

BibTeX
@article{Li2026,
  author = {Li, Yiwei and Cao, Kaiqin and Zhang, Zongcun and Jia, Xiaowei and Feng, Xuefei and Liu, Lu and Liu, Yinnian},
  title = {Polarization Calibration and Analysis of Solar-Induced Chlorophyll Fluorescence Wide-Swath Ultraspectral Imaging Spectrometer},
  journal = {Photonics},
  year = {2026},
  volume = {13},
  number = {5},
  pages = {498},
  doi = {10.3390/photonics13050498}
}
Kostenlos starten →