EUVIMEDEUVIMED entdecken
Crossref

Design and experimental validation of a modified Dyson imaging spectrometer for solar-induced chlorophyll fluorescence detection

Shanshan Zheng, Haisheng Feng, Jian Wen, Zhanjun Ling, Shuaiyin Lu, Su Wu, Lei Yu

Optics Express · 27.07.2026 · 34 (15) · 27012

DOI: 10.1364/oe.604810 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 13.07.2026. Verfasst von Shanshan Zheng und 6 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Gefördert von: Natural National Science Foundation of China, Nature Science Foundation for Distinguished Young Scholars of Anhui Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Solar-induced chlorophyll fluorescence (SIF) imaging requires spectrometers with high spectral resolution, high throughput, and compact optical layouts. We present a modified Dyson imaging spectrometer for SIF detection, in which a lens-grating combination replaces the conventional concave grating to increase the slit-to-detector distance and improve linear spectral dispersion. The optimized system achieves a spectral resolution better than 0.3 nm, RMS spot radii below 7 µm across the full field of view, smile distortion below 1.4 µm , and keystone less than 2.75 µm . A prototype spectrometer was fabricated and calibrated. Measurements with an Hg-Ar lamp show a spectral full width at half maximum of 0.274-0.297 nm, and laboratory tests demonstrate a signal-to-noise ratio above 200 within the working band. Outdoor hyperspectral imaging experiments further verify the instrument performance, and SIF images of vegetation were retrieved at 762 nm using the 3FLD method. These results demonstrate that the proposed spectrometer provides an effective solution for high-resolution SIF imaging.

Förderung

  • Natural National Science Foundation of China
  • Nature Science Foundation for Distinguished Young Scholars of Anhui Province

Zitieren

APA

Zheng, S., Feng, H., Wen, J., Ling, Z., Lu, S., Wu, S., & Yu, L. (2026). Design and experimental validation of a modified Dyson imaging spectrometer for solar-induced chlorophyll fluorescence detection. Optics Express, 34(15), 27012. https://doi.org/10.1364/oe.604810

Vancouver

Zheng S, Feng H, Wen J, Ling Z, Lu S, Wu S, et al. Design and experimental validation of a modified Dyson imaging spectrometer for solar-induced chlorophyll fluorescence detection. Optics Express. 2026;34(15):27012. doi:10.1364/oe.604810

BibTeX
@article{Zheng2026,
  author = {Zheng, Shanshan and Feng, Haisheng and Wen, Jian and Ling, Zhanjun and Lu, Shuaiyin and Wu, Su and Yu, Lei},
  title = {Design and experimental validation of a modified Dyson imaging spectrometer for solar-induced chlorophyll fluorescence detection},
  journal = {Optics Express},
  year = {2026},
  volume = {34},
  number = {15},
  pages = {27012},
  doi = {10.1364/oe.604810}
}
Kostenlos starten →