Method to Generate Chlorine Dioxide Gas In Situ for Sterilization of Automated Incubators
Pathogens · 2024
DOI: 10.3390/pathogens13111024 ↗At a glance
Journal article in Pathogens, 2024. Written by Cédric Schicklin and 4 co-authors. Institution: Bio-Inspired RObots for MEDicine-Laboratory, Department of Biomedical Engineering, University of Basel, 4123 Allschwil, Switzerland. Major MEDLINE topics: Chlorine Compounds, Sterilization, Oxides. Cited 4 times so far (Crossref); 27 references. The full text is freely available (open access, CC BY 4.0). Funded by: F. Hoffmann-La Roche Ltd. (Basel, Switzerland)., F. Hoffmann-La Roche Ltd..
Abstract (original language)
Pharmaceutical preclinical tests using cell cultures are nowadays commonly automated. Incubator microbial contaminations impact such tests. Chlorine dioxide (ClO2) is widely used in aqueous solutions. However, a gaseous form, such as chlorine dioxide gas (gClO2), can effectively access unreachable spaces, such as closed cell culture incubators. Steam sterilization requires a temperature rise to at least 121 °C, thus limiting the possibility of automation elements for sensors and actuators. gClO2 sterilization is an ambient-temperature sterilization method. This article aims to demonstrate that gClO2 generated from solid powder tablets is efficient for sterilizing incubators and can be automated. We selected (i) Bacillus subtilis strain, (ii) Saccharomyces cerevisiae, and (iii) T7 phages as representatives for (i) bacteria, (ii) fungi, and (iii) viruses for each domain to evaluate the sterilization efficiency. This study demonstrated that gClO2 can be generated inside the incubator from a solid powder tablet without specific equipment and can effectively fight biological proxies in 15 min. After 30 sterilization cycles, the actuators and sensors mounted inside the incubator were still operating. Our proposed sterilization method seems to be generally applicable for automated in situ sterilization of incubators and medical robots.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Bio-Inspired RObots for MEDicine-Laboratory, Department of Biomedical Engineering, University of Basel, 4123 Allschwil, Switzerland.
- Center for medical Image Analysis & Navigation, Department of Biomedical Engineering, University of Basel, 4123 Allschwil, Switzerland.
- Neuro Robotics Group, ARTORG Center, University of Bern, 3008 Bern, Switzerland.
- Department of Neurosurgery, Inselspital, Bern University Hospital, 3008 Bern, Switzerland.
- Biological Calorimetry Lab, Department of Biomedical Engineering, University of Basel, 4123 Allschwil, Switzerland.
ORCID profiles: Cédric Schicklin, Georg Rauter, Philippe Claude Cattin, Manuela Eugster, Olivier Braissant
Funding
- F. Hoffmann-La Roche Ltd. (Basel, Switzerland).
- F. Hoffmann-La Roche Ltd.
Cite
APA
Schicklin, C., Rauter, G., Cattin, P. C., Eugster, M., & Braissant, O. (2024). Method to Generate Chlorine Dioxide Gas In Situ for Sterilization of Automated Incubators. Pathogens. https://doi.org/10.3390/pathogens13111024
Vancouver
Schicklin C, Rauter G, Cattin PC, Eugster M, Braissant O. Method to Generate Chlorine Dioxide Gas In Situ for Sterilization of Automated Incubators. Pathogens. 2024. doi:10.3390/pathogens13111024
BibTeX
@article{Schicklin2024,
author = {Schicklin, Cédric and Rauter, Georg and Cattin, Philippe Claude and Eugster, Manuela and Braissant, Olivier},
title = {Method to Generate Chlorine Dioxide Gas In Situ for Sterilization of Automated Incubators},
journal = {Pathogens},
year = {2024},
doi = {10.3390/pathogens13111024}
}
EUVIMED