Hand Grip Force–Time Curve Indicators Evaluated by Dynamometer: A Systematic Review
Nutrients · 2024
DOI: 10.3390/nu16121951 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Nutrients, 2024. Verfasst von Tânia Silva-Santos und 3 weiteren Autor:innen. Beteiligte Einrichtung: LAETA-INEGI/FEUP, Associated Laboratory of Energy, Transports and Aerospace, Institute of Science and Innovation in Mechanical and Industrial Enginee…. Hauptthemen laut MEDLINE: Hand Strength, Muscle Strength Dynamometer. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: FCT/MCTES.
Abstract (Originalsprache)
Background
Handgrip strength (HGS) is an indicator of muscular strength, used in the diagnosis of sarcopenia, undernutrition, and physical frailty as well as recovery. Typically, the maximum HGS value is used; however, recent evidence suggests the exploration of new indicators provided based on the force–time curve to achieve a more comprehensive assessment of muscle function. Therefore, the objective was to identify indicators of the HGS profile beyond maximum HGS, based on force–time curves, and to systematize knowledge about their applications to various types of samples, health issues, and physical performance.
Methods
A systematic review was performed including studies whose participants’ HGS was assessed with a digital or adapted dynamometer. The outcome measures were HGS profile indicators calculated from the force–time curve. Results: a total of 15 studies were included, and the following indicators were identified: grip fatigue, fatigability index, fatigue rate, fatigue resistance, time to 80% maximal voluntary contraction, plateau coefficient of variability, time to maximum value, T-90%, release rate, power factor, grip work, average integrated area, endurance, cycle duration, time between cycles, maximum and minimum force–velocity, rate of grip force, final force, inflection point, integrated area, submaximal control, and response time.
Conclusions
Various indicators based on the force–time curve can be assessed through digital or adapted dynamometers. Future research should analyze these indicators to understand their implications for muscle function assessment, to standardize evaluation procedures, to identify clinically relevant measures, and to clarify their implications in clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- LAETA-INEGI/FEUP, Associated Laboratory of Energy, Transports and Aerospace, Institute of Science and Innovation in Mechanical and Industrial Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Por…
- FP-I3ID, FP-BHS, Faculty of Health Sciences, University Fernando Pessoa, 4200-150 Porto, Portugal.
- FCNAUP, Faculty of Nutrition and Food Sciences, University of Porto, 4150-180 Porto, Portugal.
- CINTESIS@RISE, MEDCIDS, Faculty of Medicine, University of Porto, 4200-450 Porto, Portugal.
ORCID-Profile: Tânia Silva-Santos, Rita S Guerra, Rui Valdiviesso, Teresa F Amaral
Förderung
- FCT/MCTES
Zitieren
APA
Silva-Santos, T., Guerra, R. S., Valdiviesso, R., & Amaral, T. F. (2024). Hand Grip Force–Time Curve Indicators Evaluated by Dynamometer: A Systematic Review. Nutrients. https://doi.org/10.3390/nu16121951
Vancouver
Silva-Santos T, Guerra RS, Valdiviesso R, Amaral TF. Hand Grip Force–Time Curve Indicators Evaluated by Dynamometer: A Systematic Review. Nutrients. 2024. doi:10.3390/nu16121951
BibTeX
@article{SilvaSantos2024,
author = {Silva-Santos, Tânia and Guerra, Rita S and Valdiviesso, Rui and Amaral, Teresa F},
title = {Hand Grip Force–Time Curve Indicators Evaluated by Dynamometer: A Systematic Review},
journal = {Nutrients},
year = {2024},
doi = {10.3390/nu16121951}
}
EUVIMED