Comparison between Two Different Handgrip Systems and Protocols on Force Reduction in Handgrip Assessment
Gerontology · 2023
DOI: 10.1159/000530227 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Gerontology, 2023. Verfasst von Liza De Dobbeleer und 8 weiteren Autor:innen. Beteiligte Einrichtung: Gerontology Department, Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium. Hauptthemen laut MEDLINE: Hand Strength, Muscle Strength Dynamometer, Muscle Fatigue, Aging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
Introduction
Fatigue resistance (FR) can be assessed as the time during which grip strength (GS) drops to 50% of its maximum during a sustained maximal voluntary contraction. For the first time, we compared force-time characteristics during FR test between two different handgrip systems and investigated age- and clinical-related differences in order to verify if a briefer test protocol (i.e., until 75%) could be sufficiently informative.
Methods
A cohort of young healthy controls (Y, <30 y, 24 ± 3 y, 54% women), middle-aged (MA, 30–65 y, 47 ± 11 y, 54% women), and older (OLD, >65 y, 77 ± 7 y, 50% women) community-dwelling persons, and hospitalized geriatric patients (HOSP, 84 ± 5 y, 50% women) performed the FR test. For this purpose, an adapted vigorimeter (original rubber bulb of the Martin Vigorimeter connected to a Unik 5000 pressure gauge) here defined as “pneumatic handgrip system” (Pneu) and Dynamometer G200 system (original Jamar Dynamometer handle with an in-build strength gauge) here defined as “hydraulic handgrip system” (Hydr) were used. Force-time curves were analysed from 100% to 75% and from 75% to 50% of the initial maximal GS during the FR test. The area under the curve (GW) was calculated by integrating the actual GS at each time interval (i.e., 1/5,000 s) and corrected for body weight (GW/body weight).
Results
For both systems, we found fair associations between FR100–50 and FR100–75 (Pneu mean difference = 50.1 s [95% CI: 47.9–52.4], r2 = 0.48; Hydr mean difference = 28.4 s [95% CI: 27.0–29.7], r2 = 0.52, all p < 0.001) and also moderate associations between GW(100–50)/body weight and GW(100–75)/body weight (Pneu mean difference = 32.1 kPa*s/kg [95% CI: 30.6–33.6], r2 = 0.72; Hydr mean difference = 8.1 kg*s/kg [95% CI: 7.7–8.6], r2 = 0.68, all p < 0.001). Between MA and OLD, we found a significant age-related difference in the GW results in the first 25% strength decay for Pneu (10.2 ± 0.6 kPa*s/kg against 7.1 ± 1.2 kPa*s/kg, respectively).
Conclusion
The brief test protocol is valid. Differences within the first 25% strength decay in GW between OLD and HOSP were identified when using Pneu but not when using Hydr. Therefore, a brief FR test protocol using a continuous registration of the strength decay seems to be sufficiently informative in a clinical setting to appraise muscle fatigability, however, only when using a Pneu system.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Gerontology Department, Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium.
- Frailty in Aging Research (FRIA) Group, Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium.
- Department of Geriatrics, Universitair Ziekenhuis Brussel, Brussels, Belgium.
- Department of Rehabilitation Sciences and Physiotherapy, Faculty of Medicine and Health Sciences, University of Antwerp, Campus Drie Eiken, Wilrijk, Belgium.
- SOMT University of Physiotherapy, Amersfoort, The Netherlands.
- Rehabilitation Sciences Research Department, Vrije Universiteit Brussel, Brussels, Belgium.
Zitieren
APA
De Dobbeleer, L., Beckwée, D., Arnold, P., Baudry, S., Beyer, I., Demarteau, J., Lieten, S., Punie, Y., & Bautmans, I. (2023). Comparison between Two Different Handgrip Systems and Protocols on Force Reduction in Handgrip Assessment. Gerontology. https://doi.org/10.1159/000530227
Vancouver
De Dobbeleer L, Beckwée D, Arnold P, Baudry S, Beyer I, Demarteau J, et al. Comparison between Two Different Handgrip Systems and Protocols on Force Reduction in Handgrip Assessment. Gerontology. 2023. doi:10.1159/000530227
BibTeX
@article{DeDobbeleer2023,
author = {De Dobbeleer, Liza and Beckwée, David and Arnold, Pauline and Baudry, Stéphane and Beyer, Ingo and Demarteau, Jeroen and Lieten, Siddhartha and Punie, Ynes and Bautmans, Ivan},
title = {Comparison between Two Different Handgrip Systems and Protocols on Force Reduction in Handgrip Assessment},
journal = {Gerontology},
year = {2023},
doi = {10.1159/000530227}
}
EUVIMED