EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Room-Temperature CH4 Detection Using PLD-Deposited ZnO/CuO and ZnO/In2O3 Bilayer SAW Sensors

Izabela Constantinoiu iD, Cristian Viespe iD, Cornelia Enache

Nanomaterials · 29.10.2026 · 16 (21) · 1390

DOI: 10.3390/nano16211390 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nanomaterials, online erschienen am 29.10.2026. Verfasst von Izabela Constantinoiu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Laser Department, National Institute for Laser, Plasma and Radiation Physics, Atomistilor 409, 077125 Magurele, Romania. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Research and Innovation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates ZnO-based surface acoustic wave (SAW) sensors for the detection of methane (CH4) at room temperature (RT), focusing on the influence of film morphology and oxide heterostructures developed by pulsed laser deposition (PLD). Bilayer thin films—specifically ZnO/CuO and ZnO/In2O3—were deposited onto quartz substrates at 400 °C under oxygen pressures of 100 and 700 mTorr to evaluate how deposition conditions affect sensor performance. Structural and morphological characterization was performed using X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS). ZnO thin films deposited at 700 mTorr exhibited a more open, granular morphology compared to those deposited at 100 mTorr, a feature likely to facilitate gas access to the sensor’s active surface. The addition of CuO and In2O3 top layers further influenced the sensor response, presumably through surface and interface effects. Among the configurations studied, sensor S6 (ZnO/CuO, with both layers deposited at 700 mTorr) demonstrated the highest sensitivity—0.18 Hz/ppm—within the experimentally investigated CH4 concentration range (0.4–2%), with an estimated limit of detection (LOD) of 167 ppm. Short-term measurements performed on sensors S4 and S6 at a 2% CH4 concentration indicated reversible responses over two consecutive exposure and recovery cycles, with a return to the initial baseline value following the removal of the gas. These results suggest that ZnO-based double layers, fabricated via PLD, are promising candidates for further investigation as CH4-sensitive layers at RT.

Schlagwörter

Stichwörter der Autor:innen

copper oxideindium oxidelaser ablationmethaneroom-temperature gas sensingsurface acoustic wave sensorzinc oxide

Autor:innen und Institutionen

  • Laser Department, National Institute for Laser, Plasma and Radiation Physics, Atomistilor 409, 077125 Magurele, Romania.

ORCID-Profile: Izabela Constantinoiu, Cristian Viespe

Förderung

  • Ministry of Research and Innovation

Zitieren

APA

Constantinoiu, I., Viespe, C., & Enache, C. (2026). Room-Temperature CH4 Detection Using PLD-Deposited ZnO/CuO and ZnO/In2O3 Bilayer SAW Sensors. Nanomaterials, 16(21), 1390. https://doi.org/10.3390/nano16211390

Vancouver

Constantinoiu I, Viespe C, Enache C. Room-Temperature CH4 Detection Using PLD-Deposited ZnO/CuO and ZnO/In2O3 Bilayer SAW Sensors. Nanomaterials. 2026;16(21):1390. doi:10.3390/nano16211390

BibTeX
@article{Constantinoiu2026,
  author = {Constantinoiu, Izabela and Viespe, Cristian and Enache, Cornelia},
  title = {Room-Temperature CH4 Detection Using PLD-Deposited ZnO/CuO and ZnO/In2O3 Bilayer SAW Sensors},
  journal = {Nanomaterials},
  year = {2026},
  volume = {16},
  number = {21},
  pages = {1390},
  doi = {10.3390/nano16211390}
}
Kostenlos starten →