Machine Learning-Enabled ZnS/In2O3 Heterojunction Sensors for ppb-Level Room-Temperature Hydrogen Detection
ACS Sensors · 30.10.2026
DOI: 10.1021/acssensors.6c03864 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 30.10.2026. Verfasst von Suraj Barala und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Aerospace Engineering, Indian Institute of Technology Jodhpur, Jodhpur342030, India. Die Arbeit nennt 72 Literaturangaben. Gefördert von: Board of Research in Nuclear Sciences.
Abstract (Originalsprache)
Real-time, ppm-to-ppb-level detection of hydrogen (H2) remains essential for industrial safety, given its flammability and widespread use in energy applications. Portable H2 sensors, however, continue to suffer from insufficient sensitivity and reliance on elevated operating temperatures. Here, cubic bixbyite In2O3 nanocubes, synthesized by radio frequency sputtering at 600 °C, were functionalized via drop-cast decoration with ZnS nanoparticles to form an n–n heterojunction for H2 sensing at room temperature (∼32 °C). The ZnS/In2O3 architecture leverages a high surface area, oxygen vacancy-mediated adsorption, and catalytic spillover from ZnS to enhance H2 interaction and charge carrier modulation. Pristine In2O3 showed a relative response of 11.23% to 50 ppm H2, which increased to ∼23% upon optimal ZnS loading (48 wt %), with a detection limit of 86.9 ppb and response/recovery times of ∼90 s/∼488 s. To enable quantitative concentration estimation, a two-stage machine learning framework was developed using six transient response features (Smax, Trsp (90%), Trec (90%), ∫Rdt, mean dR/dt, and ∫R/s). Permutation importance identified Trec (90%), mean dR/dt, and ∫R/s as dominant predictors, while principal component analysis captured 91.8% variance with clear concentration-dependent clustering. Among four regressors evaluated via 5-fold cross-validation, Gaussian process regression achieved the best static prediction (root-mean-square error (RMSE) = 4.044 ppm, R2 = 0.945), while a 15 s sliding-window multilayer perceptron model with Bayesian-optimized hyperparameters enabled real-time tracking (RMSE = 3.837 ppm, mean absolute error = 1.263 ppm, and R2 = 0.924) across 0.5–50 ppm, with sub-5 ppm resolution well below the 4 vol % lower flammability limits. These results establish a combined materials and data-driven strategy for robust, ambient-temperature H2 monitoring.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Aerospace Engineering, Indian Institute of Technology Jodhpur, Jodhpur342030, India.
- Department of Electronics Engineering, Indian Institute of Technology Jodhpur, Jodhpur342030, India.
- Department of Electrical Engineering, Indian Institute of Technology Jodhpur, Jodhpur342030, India.
- Department of Cybernetics, Nanotechnology and Data Processing, Faculty of Automatic Control, Electronics and Computer Science, Silesian University of Technology, Akademicka 16, Gliwice44-100, Poland.
- Department of Mechanical Engineering, Indian Institute of Technology Jodhpur, Jodhpur342030, India.
ORCID-Profile: Vikas Pandey, Ashok Kumar, Ankur Gupta, Mahesh Kumar
Förderung
- Board of Research in Nuclear Sciences
Zitieren
APA
Barala, S., Pandey, V., Kumar, A., Kumar, A., Kwoka-Czornik, M., Gupta, A., & Kumar, M. (2026). Machine Learning-Enabled ZnS/In2O3 Heterojunction Sensors for ppb-Level Room-Temperature Hydrogen Detection. ACS Sensors. https://doi.org/10.1021/acssensors.6c03864
Vancouver
Barala S, Pandey V, Kumar A, Kumar A, Kwoka-Czornik M, Gupta A, et al. Machine Learning-Enabled ZnS/In2O3 Heterojunction Sensors for ppb-Level Room-Temperature Hydrogen Detection. ACS Sensors. 2026. doi:10.1021/acssensors.6c03864
BibTeX
@article{Barala2026,
author = {Barala, Suraj and Pandey, Vikas and Kumar, Amit and Kumar, Ashok and Kwoka-Czornik, Monika and Gupta, Ankur and Kumar, Mahesh},
title = {Machine Learning-Enabled ZnS/In2O3 Heterojunction Sensors for ppb-Level Room-Temperature Hydrogen Detection},
journal = {ACS Sensors},
year = {2026},
doi = {10.1021/acssensors.6c03864}
}
EUVIMED