EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accuracy of Measurements of Thermophysical Parameters by Dual-Beam Thermal-Lens Spectrometry

Vladislav R Khabibullin iD, Mladen Franko, Mikhail A Proskurnin iD

Nanomaterials · 20.01.2023 · 13 (3) · 430

DOI: 10.3390/nano13030430 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nanomaterials, online erschienen am 20.01.2023. Verfasst von Vladislav R Khabibullin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Analytical Chemistry Division, Chemistry Department, M.V. Lomonosov Moscow State University, d. 1, str. 3, Lenin Hills, GSP-1 V-234, Moscow 119991, R…. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 98 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Russian Foundation for Basic Research, RFBR and Moscow city Government, ARRS-Slovenian Research Agency.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Thermal-lens spectrometry is a sensitive technique for determination of physicochemical properties and thermophysical parameters of various materials including heterogeneous systems and nanoparticles. In this paper, we consider the issues of the correctness (trueness) of measurements of the characteristic time of the thermal-lens effect and, thus, of the thermal diffusivity determined by dual-beam mode-mismatching thermal lensing. As sources of systematic errors, major factors—radiation sources, sample-cell and detector parameters, and general measurement parameters—are considered using several configurations of the thermal-lens setups, and their contributions are quantified or estimated. Furthermore, with aqueous ferroin and Sudan I in ethanol as inert colorants, the effects of the intermolecular distance of the absorbing substance on the correctness of finding the thermophysical parameters are considered. The recommendations for checking the operation of the thermal-lens setup to ensure the maximum accuracy are given. The results obtained help reducing the impact of each investigated factor on the value of systematic error and correctly measure the thermophysical parameters using thermal-lens spectrometry.

Schlagwörter

Stichwörter der Autor:innen

accuracy and truenessmeasurements of thermal diffusivitymode-mismatched schematicthermal-lens spectrometry

Autor:innen und Institutionen

  • Analytical Chemistry Division, Chemistry Department, M.V. Lomonosov Moscow State University, d. 1, str. 3, Lenin Hills, GSP-1 V-234, Moscow 119991, Russia.
  • Laboratory for Environmental and Life Sciences, University of Nova Gorica, Vipavska 13, Rožna Dolina, 5000 Nova Gorica, Slovenia.

ORCID-Profile: Vladislav R Khabibullin, Mikhail A Proskurnin

Förderung

  • Russian Foundation for Basic Research
  • RFBR and Moscow city Government
  • ARRS-Slovenian Research Agency

Zitieren

APA

Khabibullin, V. R., Franko, M., & Proskurnin, M. A. (2023). Accuracy of Measurements of Thermophysical Parameters by Dual-Beam Thermal-Lens Spectrometry. Nanomaterials, 13(3), 430. https://doi.org/10.3390/nano13030430

Vancouver

Khabibullin VR, Franko M, Proskurnin MA. Accuracy of Measurements of Thermophysical Parameters by Dual-Beam Thermal-Lens Spectrometry. Nanomaterials. 2023;13(3):430. doi:10.3390/nano13030430

BibTeX
@article{Khabibullin2023,
  author = {Khabibullin, Vladislav R and Franko, Mladen and Proskurnin, Mikhail A},
  title = {Accuracy of Measurements of Thermophysical Parameters by Dual-Beam Thermal-Lens Spectrometry},
  journal = {Nanomaterials},
  year = {2023},
  volume = {13},
  number = {3},
  pages = {430},
  doi = {10.3390/nano13030430}
}
Kostenlos starten →