Achieving ppm-Level Precision and Accuracy in Triple Silicon Isotope Measurements by Gas Source Isotope Ratio Mass Spectrometry
Analytical Chemistry · 29.10.2026
DOI: 10.1021/acs.analchem.6c04220 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 29.10.2026. Verfasst von Jiayi Wu und 5 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Gefördert von: Fundo para o Desenvolvimento das Ciências e da Tecnologia, Fundamental Research Funds for the Central Universities, National Basic Research Program of China (973 Program).
Abstract (Originalsprache)
Triple silicon isotopes, expressed as Δ’29Si, the deviation of δ’29Si from the high-temperature equilibrium mass-dependent fractionation reference, provide an additional dimension for distinguishing fractionation processes that can produce overlapping single-isotope (δ’30Si or δ’29Si) signatures, making them useful for investigating terrestrial planet accretion and silicon cycling on Earth. However, their broader application has been limited by the analytical precision and accuracy required to resolve the subtle Δ’29Si variations observed in natural samples. Here, we present an analytical protocol that achieves an external reproducibility of ∼1 ppm (1 SD) for Δ’29Si using gas source isotope ratio mass spectrometry (Thermo Fisher Scientific Ultra HR-IRMS). Silicates are quantitatively converted to BaSiF6 and subsequently thermally decomposed to SiF4 for isotopic analysis. This approach avoids strong oxidizing fluorination reagents and minimizes potential sources of sulfur-bearing fluorination by-products. Systematic SO2F2 mixing experiments demonstrate that the diagnostic m/z 88 ion can be used as an empirical quality-control parameter for identifying measurements affected by sulfur-bearing isobaric interference at m/z 86. Long-term zero-enrichment tests and full-procedure analyses of reference materials demonstrate reproducibility of approximately 1 ppm for Δ’29Si. Application to three Mesoproterozoic chert samples from the Jixian Group yields Δ’29Si values of −4.1 ± 0.3 to −16.9 ± 1.8 ppm and a δ’30Si−δ’29Si regression slope of 0.5104 ± 0.0008 (1 SD), broadly consistent with previously reported Jixian chert compositions. The analytical protocol provides a practical approach for resolving subtle triple silicon isotope variations in natural geological materials, supporting future geochemical and planetary studies.
Förderung
- Fundo para o Desenvolvimento das Ciências e da Tecnologia
- Fundamental Research Funds for the Central Universities
- National Basic Research Program of China (973 Program)
- National Natural Science Foundation of China (NSFC)
- GeoX Interdisciplinary Project of Frontiers Science Center for Critical Earth Material Cycling
- State Key Laboratory of Critical Earth Material Cycling and Mineral Deposits
Zitieren
APA
Wu, J., Rao, Y., Tong, F., Yu, H., Pack, A., & Cao, X. (2026). Achieving ppm-Level Precision and Accuracy in Triple Silicon Isotope Measurements by Gas Source Isotope Ratio Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c04220
Vancouver
Wu J, Rao Y, Tong F, Yu H, Pack A, Cao X. Achieving ppm-Level Precision and Accuracy in Triple Silicon Isotope Measurements by Gas Source Isotope Ratio Mass Spectrometry. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c04220
BibTeX
@article{Wu2026,
author = {Wu, Jiayi and Rao, Yinghua and Tong, Fengtai and Yu, Huimin and Pack, Andreas and Cao, Xiaobin},
title = {Achieving ppm-Level Precision and Accuracy in Triple Silicon Isotope Measurements by Gas Source Isotope Ratio Mass Spectrometry},
journal = {Analytical Chemistry},
year = {2026},
doi = {10.1021/acs.analchem.6c04220}
}
EUVIMED