Intra-Rater, Inter-Rater, and Test–Retest Reliability of a Laser- and Inclinometer-Based Hip Joint Position Sense Test in Healthy Adults: A Two-Phase Study with Preliminary Reference Values
Muscles · 19.06.2026 · 5 (2) · 45
DOI: 10.3390/muscles5020045 ↗Kurz gefasst
Fachartikel in der Zeitschrift Muscles, online erschienen am 19.06.2026. Verfasst von Joévin Burnel und 3 weiteren Autor:innen. Beteiligte Einrichtung: Research Unit in Rehabilitation Sciences, Faculty of Human Movement Sciences, Université Libre de Bruxelles, Route de Lennik 808, 1070 Bruxelles, Bel…. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Hip joint position sense (JPS), a key component of neuromuscular function arising from muscle spindle and periarticular mechanoreceptor input, remains underexplored, with no standardized and reliable clinical protocol available to assess hip proprioception. This study evaluated the intra- and inter-rater reliability of a laser- and inclinometer-based active hip JPS protocol and established preliminary references in healthy adults. A two-phase reliability study was conducted in accordance with GRRAS and COSMIN guidelines: 17 participants for reliability analyses and 57 for preliminary references. Six movement directions were assessed (flexion, extension, abduction, adduction, medial and lateral rotations). Reliability was quantified using intraclass correlation coefficients with their 95% confidence intervals, using two-way random-effects models with absolute agreement (ICC(3,1) for intra-rater and ICC(2,1) for inter-rater analyses), interpreted as poor (
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research Unit in Rehabilitation Sciences, Faculty of Human Movement Sciences, Université Libre de Bruxelles, Route de Lennik 808, 1070 Bruxelles, Belgium.
- Conseil Scientifique de TOHA, Thread of Life Prime, 37000 Tours, France.
- Institut de Formation en Masso-Kinésithérapie de L'Est-Francilien (IFMKEF), 77124 Chauconin-Neufmontiers, France.
- Ramsay Santé, Clinique de la Sauvegarde, 69009 Lyon, France.
- Lyon Ortho Clinic Global, 69009 Lyon, France.
- Interuniversity Laboratory of Human Movement Biology, Claude Bernard University Lyon 1, 69010 Villeurbanne, France.
ORCID-Profile: Joévin Burnel, Benoit Pairot de Fontenay, Joachim Van Cant
Zitieren
APA
Burnel, J., Vallee, B., Pairot de Fontenay, B., & Van Cant, J. (2026). Intra-Rater, Inter-Rater, and Test–Retest Reliability of a Laser- and Inclinometer-Based Hip Joint Position Sense Test in Healthy Adults: A Two-Phase Study with Preliminary Reference Values. Muscles, 5(2), 45. https://doi.org/10.3390/muscles5020045
Vancouver
Burnel J, Vallee B, Pairot de Fontenay B, Van Cant J. Intra-Rater, Inter-Rater, and Test–Retest Reliability of a Laser- and Inclinometer-Based Hip Joint Position Sense Test in Healthy Adults: A Two-Phase Study with Preliminary Reference Values. Muscles. 2026;5(2):45. doi:10.3390/muscles5020045
BibTeX
@article{Burnel2026,
author = {Burnel, Joévin and Vallee, Benoit and Pairot de Fontenay, Benoit and Van Cant, Joachim},
title = {Intra-Rater, Inter-Rater, and Test–Retest Reliability of a Laser- and Inclinometer-Based Hip Joint Position Sense Test in Healthy Adults: A Two-Phase Study with Preliminary Reference Values},
journal = {Muscles},
year = {2026},
volume = {5},
number = {2},
pages = {45},
doi = {10.3390/muscles5020045}
}
EUVIMED