EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

SPE-HPLC-DAD Dosage of Seven Neonicotinoids in Green Coffee

Serenella Seccia, Stefania Albrizio iD, Irene Dini iD

Molecules · 2025

DOI: 10.3390/molecules30091930 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, 2025. Verfasst von Serenella Seccia und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, University of Naples Federico II, Via Domenico Montesano 49, 80131 Napoli, Italy. Hauptthemen laut MEDLINE: Neonicotinoids, Coffee, Solid Phase Extraction, Pesticide Residues. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Green coffee is essential in many tropical economies. Its cultivation often necessitates using pesticides that can leave behind residues harmful to human health. To ensure consumer safety, the European Community has set strict maximum residue limits (ranging from 0.01 to 1.0 mg/kg) for pesticides in green coffee sold within Europe. However, the lack of official testing methods for neonicotinoids (NEOs) is a problem, as laboratories must spend resources and time developing and validating suitable analytical methods. This study developed and validated a method for the simultaneous analysis of seven NEOs frequently used in coffee cultivation: acetamiprid, clothianidin, dinotefuran, imidacloprid, nitenpyram, thiacloprid, and thiamethoxam. The proposed methodology uses Strata®-X PRO cartridges (solid-phase extraction) to remove interfering compounds present in the food matrix and high-performance liquid chromatography (HPLC), equipped with a diode array detector (DAD), to determine NEOs. The accuracy profile strategy validated the method’s suitability for the intended application. NEO recovery rates above 97%; negligible matrix effects (>93%); the linearity of the quantification method (R2 values above 0.99); relative biases and standard deviations below 5% and 6%, respectively; and an expected error rate less than 8% allowed to consider the method reliable for the intended objectives. Because of its low ecological impact and simple execution, this method can be used in routine analyses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NeonicotinoidsCoffeeSolid Phase ExtractionPesticide ResiduesChromatography, High Pressure LiquidThiamethoxamNitro CompoundsGuanidinesReproducibility of ResultsThiazolesThiazines

Stichwörter der Autor:innen

SPE-HPLC/DADchemical method validationfood safetygreen coffeeneonicotinoidspesticide analysis

Substanzen

NeonicotinoidsCoffeePesticide ResiduesthiaclopridacetamipridclothianidinThiamethoxamdinotefuranNitro CompoundsGuanidines

Autor:innen und Institutionen

  • Department of Pharmacy, University of Naples Federico II, Via Domenico Montesano 49, 80131 Napoli, Italy.

ORCID-Profile: Stefania Albrizio, Irene Dini

Zitieren

APA

Seccia, S., Albrizio, S., & Dini, I. (2025). SPE-HPLC-DAD Dosage of Seven Neonicotinoids in Green Coffee. Molecules. https://doi.org/10.3390/molecules30091930

Vancouver

Seccia S, Albrizio S, Dini I. SPE-HPLC-DAD Dosage of Seven Neonicotinoids in Green Coffee. Molecules. 2025. doi:10.3390/molecules30091930

BibTeX
@article{Seccia2025,
  author = {Seccia, Serenella and Albrizio, Stefania and Dini, Irene},
  title = {SPE-HPLC-DAD Dosage of Seven Neonicotinoids in Green Coffee},
  journal = {Molecules},
  year = {2025},
  doi = {10.3390/molecules30091930}
}
Kostenlos starten →