Graphyne modified with polymeric deep eutectic solvent via unsaturated bond engineering for imidacloprid and diuron analysis: Bond-regulated interfacial adsorption
Journal of Chromatography A · 2026-12 · 1790 · 467572
DOI: 10.1016/j.chroma.2026.467572 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2026-12. Verfasst von Man Huang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Pharmaceutical Quality Control of Hebei Province, College of Pharmaceutical Sciences, Hebei University, Baoding, 071002, China; Sta…. Hauptthemen laut MEDLINE: Nitro Compounds, Neonicotinoids, Graphite, Diuron. Die Arbeit nennt 31 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
To address the demand for high-performance adsorbents in trace pesticide residue detection in complex matrices, a gradient series of deep eutectic solvents (DESs) bearing alkenyl, alkynyl and aryl unsaturated bonds was constructed, and a series of DES/polymeric DES (PDES) functionalized hydrogen-substituted graphyne (HsGY) composites were prepared for sample pretreatment. The regulatory effects of unsaturated bond types and polymerization on adsorption performance were systematically elucidated. Alkenyl DESs were polymerized into flexible saturated backbones with fully exposed active sites, leading to enhanced adsorption capacity, whereas alkynyl DESs resulted in decreased capacity due to tight chain stacking and active site entrapment. Density functional theory calculations confirmed that enhanced orbital delocalization after polymerization, together with synergistic hydrogen bonding, electrostatic interactions and charge transfer, underpinned the performance improvement in alkenyl systems. Based on the optimal PDES2-HsGY, a pipette-tip solid-phase extraction-HPLC method was established for simultaneous enrichment and trace detection of imidacloprid and diuron in honeysuckle and green tea samples. The method showed good linearity in the range of 0.05-10 μg·g-1, with limits of detection of 0.008-0.012 μg·g-1, spiked recoveries of 82.12%-94.72%, and RSDs ≤5.71%. The adsorbent exhibited superior performance to various commercial sorbents, providing a reference for the structural design of DES-based separation materials.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Pharmaceutical Quality Control of Hebei Province, College of Pharmaceutical Sciences, Hebei University, Baoding, 071002, China; State Key Laboratory of New Pharmaceutical Preparations and Excipients, K…
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Huang, M., Wu, Y., Qiao, X., & Zhu, T. (2026). Graphyne modified with polymeric deep eutectic solvent via unsaturated bond engineering for imidacloprid and diuron analysis: Bond-regulated interfacial adsorption. Journal of Chromatography A, 1790, 467572. https://doi.org/10.1016/j.chroma.2026.467572
Vancouver
Huang M, Wu Y, Qiao X, Zhu T. Graphyne modified with polymeric deep eutectic solvent via unsaturated bond engineering for imidacloprid and diuron analysis: Bond-regulated interfacial adsorption. Journal of Chromatography A. 2026;1790:467572. doi:10.1016/j.chroma.2026.467572
BibTeX
@article{Huang2026,
author = {Huang, Man and Wu, Yifeng and Qiao, Xiaoqiang and Zhu, Tao},
title = {Graphyne modified with polymeric deep eutectic solvent via unsaturated bond engineering for imidacloprid and diuron analysis: Bond-regulated interfacial adsorption},
journal = {Journal of Chromatography A},
year = {2026},
volume = {1790},
pages = {467572},
doi = {10.1016/j.chroma.2026.467572}
}
EUVIMED