Determination of Lactoferrin Using High-Frequency Piezoelectric Quartz Aptamer Biosensor Based on Molecular Bond Rupture
Molecules · 2024
DOI: 10.3390/molecules29235699 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, 2024. Verfasst von Haizhi Wu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Hunan Provincial Institute of Product and Goods Quality Inspection, Changsha 410007, China. Hauptthemen laut MEDLINE: Lactoferrin, Biosensing Techniques, Aptamers, Nucleotide, Quartz Crystal Microbalance Techniques. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of Hunan Province, Hunan Provincial Market Supervision Administration Science and Technology Plan Project, State Administration for Market Regulation Science and Technology Plan Project.
Abstract (Originalsprache)
In this study, an aptamer biosensor for detecting lactoferrin (LF) was developed using piezoelectric quartz-induced bond rupture sensing technology. The thiol-modified aptamer I was immobilized on the gold electrode surface of the quartz crystal microbalance (QCM) through an Au-S bond to specifically bind LF. It was then combined with aptamer–magnetic beads to amplify the mass signal. The peak excitation voltage was 8 V at the resonance frequency for the 60 MHz gold-plated quartz crystal. When the molecular bond cracking process occurred, the aptamer–magnetic beads combined on the surface of the piezoelectric quartz were removed, which resulted in an increase in quartz crystal resonance frequency. Therefore, the specific detection of LF can be realized. Under optimized experimental conditions, the linear range for LF was 10–500 ng/mL, the detection limit (3σ) was 8.2 ng/mL, and the sample recoveries for actual milk powder samples ranged from 97.2% to 106.0%. Compared with conventional QCM sensing technology, the signal acquisition process of this sensing method is simple, fast, and easy to operate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Hunan Provincial Institute of Product and Goods Quality Inspection, Changsha 410007, China.
- College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.
Förderung
- National Natural Science Foundation of Hunan Province
- Hunan Provincial Market Supervision Administration Science and Technology Plan Project
- State Administration for Market Regulation Science and Technology Plan Project
Zitieren
APA
Wu, H., Si, S., Li, Z., Su, J., Jia, S., He, H., Peng, C., Cheng, T., & Wu, Q. (2024). Determination of Lactoferrin Using High-Frequency Piezoelectric Quartz Aptamer Biosensor Based on Molecular Bond Rupture. Molecules. https://doi.org/10.3390/molecules29235699
Vancouver
Wu H, Si S, Li Z, Su J, Jia S, He H, et al. Determination of Lactoferrin Using High-Frequency Piezoelectric Quartz Aptamer Biosensor Based on Molecular Bond Rupture. Molecules. 2024. doi:10.3390/molecules29235699
BibTeX
@article{Wu2024,
author = {Wu, Haizhi and Si, Shihui and Li, Zheng and Su, Jiayou and Jia, Shangguan and He, Hao and Peng, Chengcheng and Cheng, Tongqiang and Wu, Qian},
title = {Determination of Lactoferrin Using High-Frequency Piezoelectric Quartz Aptamer Biosensor Based on Molecular Bond Rupture},
journal = {Molecules},
year = {2024},
doi = {10.3390/molecules29235699}
}
EUVIMED