Application of the Combined QCM-D/LSPR Aptasensor for Penicillin G Detection
Biosensors · 2025
DOI: 10.3390/bios15100652 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Sandro Spagnolo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynska Dolina F1, 84248 Bratislava, Slovakia. Hauptthemen laut MEDLINE: Quartz Crystal Microbalance Techniques, Surface Plasmon Resonance, Aptamers, Nucleotide, Biosensing Techniques. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, European Commision, The Science Agency VEGA.
Abstract (Originalsprache)
Penicillin G (PEN) is a widely used antibiotic for treating microbial infections. However, its extensive use in veterinary medicine can lead to accumulation in animal-derived products, particularly milk and meat. This highlights the urgent need for rapid and sensitive antibiotic detection methods. In this study, we employed DNA aptamers for the detection of PEN and for the analysis of aptamer specificity using a combined approach based on quartz crystal microbalance with dissipation monitoring (QCM-D) and localized surface plasmon resonance (LSPR). QCM-D measures changes in resonant frequency, Δf, and dissipation, ΔD, while LSPR monitors wavelength shifts in the extinction spectra corresponding to changes at the surface of gold nanoparticles (AuNPs). Thiolated aptamers were chemisorbed onto the surface of AuNPs with a diameter of 80 nm. In the presence of PEN, a redshift in the extinction spectra and a decrease in resonant frequency were observed, accompanied by an increase in dissipation due to surface viscosity effects. Significant changes in both acoustic and LSPR signals were observed at PEN concentrations as low as 1 nM. The limits of detection (LOD) for PEN, determined by QCM-D (3.0 nM, or 1.05 ng/mL)) and LSPR (3.1 nM, or 1.09 ng/mL), were similar and both were lower than the maximum residue limit (MRL) for PEN established by the EU (4 ng/mL).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynska Dolina F1, 84248 Bratislava, Slovakia.
- Leibniz Institute of Photonic Technology (Leibniz-IPHT), A. Einstein Str. 9, 07745 Jena, Germany.
ORCID-Profile: Andrea Csaki, Katrin Wondraczek, Wolfgang Fritzsche, Tibor Hianik
Förderung
- European Commission
- European Commision
- The Science Agency VEGA
- German Academic Exchange Service
- European Union’s Horizon 2020 research and innovation program
- EU Horizon2020 Actphast4R GA
- BMBF, Clusters4Future
- DAAD PPP project
Zitieren
APA
Spagnolo, S., Sontakke, K., Dubbert, L., Urban, M., Lednicky, T., Csaki, A., Wondraczek, K., Fritzsche, W., & Hianik, T. (2025). Application of the Combined QCM-D/LSPR Aptasensor for Penicillin G Detection. Biosensors. https://doi.org/10.3390/bios15100652
Vancouver
Spagnolo S, Sontakke K, Dubbert L, Urban M, Lednicky T, Csaki A, et al. Application of the Combined QCM-D/LSPR Aptasensor for Penicillin G Detection. Biosensors. 2025. doi:10.3390/bios15100652
BibTeX
@article{Spagnolo2025,
author = {Spagnolo, Sandro and Sontakke, Kiran and Dubbert, Lukas and Urban, Matthias and Lednicky, Tomas and Csaki, Andrea and Wondraczek, Katrin and Fritzsche, Wolfgang and Hianik, Tibor},
title = {Application of the Combined QCM-D/LSPR Aptasensor for Penicillin G Detection},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15100652}
}
EUVIMED