EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Rapid Determination of Tetracyclines in Drinking and Environmental Waters Using Fully Automatic Solid-Phase Extraction with Ultra-Performance Liquid Chromatography–Tandem Mass Spectrometry

Tongtong Zhang, Xiangyang Zhang, Jiangmei Yu, Hongmei Hu iD, Pengfei He, Zhenhua Li, Yi Fang, Tiejun Li, Yuanming Guo

Molecules · 2024

DOI: 10.3390/molecules29122921 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, 2024. Verfasst von Tongtong Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Marine and Fisheries, Zhejiang Ocean University, Zhoushan 316021, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Solid Phase Extraction, Tetracyclines, Water Pollutants, Chemical. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Science and technology project of Zhejiang Province, China, Science and Technology Project of Zhejiang Province, China, Science and Technology Project of Zhoushan, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The abuse and irrational use of tetracyclines (TCs) in human medicine and animal husbandry has become a serious concern, affecting the ecological environment and human health. The aim of this study was to develop a sensitive and selective method using fully automatic solid-phase extraction coupled with ultra-performance liquid chromatography–tandem mass spectrometry for the determination of twelve TCs in water. Four isotope-labeled internal standards for TCs were used to correct matrix effects. Several parameters affecting extraction efficiency were systematically optimized, and the optimum experimental conditions found were 1.0 L water sample with 0.5 g/L Na2EDTA (pH 3.0) extracted and enriched by CNW HLB cartridge and eluted by 4 mL of acetone:methanol (v/v, 1:1). The enrichment factors were up to 798−1059 but only requiring about 60 min per six samples. Under the optimized conditions, the linearity of the method ranged from 0.2 to 100 μg/L for 12 TCs, the detection limits were as low as 0.01−0.15 ng/L, and the recoveries were in the range of 70%–118%, with relative standard deviations less than 15%. The developed method can be successfully utilized for the determination of 12 TCs in pure water, tap water, river water, and mariculture seawater. In summary, three and six TCs were detected in river water and mariculture seawater, respectively, with total concentrations of 0.074–0.520 ng/L (mean 0.248 ng/L) and 0.792–58.369 ng/L (12.629 ng/L), respectively. Tetracycline (TC) and oxytetracycline (OTC) were the dominant TCs in river water, while doxytetracycline (DXC) and OTC were dominant in mariculture seawater.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometrySolid Phase ExtractionTetracyclinesWater Pollutants, ChemicalDrinking WaterChromatography, High Pressure LiquidLimit of Detection

Stichwörter der Autor:innen

automated solid-phase extractionisotope dilutiontetracyclinesultra-performance liquid chromatography–tandem mass spectrometrywater matrix

Substanzen

TetracyclinesWater Pollutants, ChemicalDrinking Water

Autor:innen und Institutionen

  • Institute of Marine and Fisheries, Zhejiang Ocean University, Zhoushan 316021, China.
  • Key Laboratory of Sustainable Utilization of Technology Research for Fisheries Resources of Zhejiang Province, Zhejiang Marine Fisheries Research Institute, Zhoushan 316021, China.
  • Daishan County Science and Technology Innovation Center, Zhoushan 316200, China.
  • Zhoushan Ecological Environment Protection Technology Center, Zhoushan 316021, China.

ORCID-Profile: Hongmei Hu

Förderung

  • the Science and technology project of Zhejiang Province, China
  • Science and Technology Project of Zhejiang Province, China
  • Science and Technology Project of Zhoushan, China

Zitieren

APA

Zhang, T., Zhang, X., Yu, J., Hu, H., He, P., Li, Z., Fang, Y., Li, T., & Guo, Y. (2024). Rapid Determination of Tetracyclines in Drinking and Environmental Waters Using Fully Automatic Solid-Phase Extraction with Ultra-Performance Liquid Chromatography–Tandem Mass Spectrometry. Molecules. https://doi.org/10.3390/molecules29122921

Vancouver

Zhang T, Zhang X, Yu J, Hu H, He P, Li Z, et al. Rapid Determination of Tetracyclines in Drinking and Environmental Waters Using Fully Automatic Solid-Phase Extraction with Ultra-Performance Liquid Chromatography–Tandem Mass Spectrometry. Molecules. 2024. doi:10.3390/molecules29122921

BibTeX
@article{Zhang2024,
  author = {Zhang, Tongtong and Zhang, Xiangyang and Yu, Jiangmei and Hu, Hongmei and He, Pengfei and Li, Zhenhua and Fang, Yi and Li, Tiejun and Guo, Yuanming},
  title = {Rapid Determination of Tetracyclines in Drinking and Environmental Waters Using Fully Automatic Solid-Phase Extraction with Ultra-Performance Liquid Chromatography–Tandem Mass Spectrometry},
  journal = {Molecules},
  year = {2024},
  doi = {10.3390/molecules29122921}
}
Kostenlos starten →