EUVIMEDEUVIMED entdecken
Crossref

Natural Biosorbents for Detecting Emerging Contaminants in Tap and River Water via Pipette Tip Solid‐Phase Extraction (PT‐SPE)

Hassen Khazri iD, Samir Touaylia, Malika Trabelsi-Ayadi, Riadh Ternane, Ibtissem Ghorbel-Abid

Biomedical Chromatography · 2025

DOI: 10.1002/bmc.70187 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, 2025. Verfasst von Hassen Khazri und 4 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory for Applications of Chemistry to Resources, Natural Substances and Environment (LACReSNE). Carthage University, Faculty of Sciences of Biz…. Hauptthemen laut MEDLINE: Solid Phase Extraction, Water Pollutants, Chemical, Rivers, Drinking Water. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, a pipette tip solid‐phase extraction (PT‐SPE) method was developed using cork powder as a natural biosorbent for the extraction of five pharmaceutical contaminants: diclofenac, ibuprofen, ketoprofen, bezafibrate, and fenoprofen. The method was applied to both spiked tap water and real river water samples. The cork powder was characterized using Fourier Transform Infrared Spectroscopy (FTIR), Scanning Electron Microscopy (SEM), and Brunauer–Emmett–Teller (BET) analysis to assess its functional groups, morphology, and surface properties. The analytes were separated and quantified using reverse‐phase high‐performance liquid chromatography (RP‐HPLC) with UV detection at 226 nm. Method optimization was performed by evaluating key parameters, including the amount of adsorbent, sample volume, and desorption solvent. The developed method demonstrated low limits of detection (LOD) ranging from 0.68 to 1.22 μg/L −1 and limits of quantification (LOQ) between 2.06 and 3.68 μg/L −1 . The calibration curves exhibited good linearity ( R 2 = 0.978–0.996) over the concentration range of 5–200 μg/L −1 . Satisfactory recoveries were obtained, ranging from 80.32% to 103.3%, with relative standard deviations (RSD) below 6.3%. In real river water samples, some analytes were detected even in non‐spiked conditions, whereas no contamination was observed in non‐spiked tap water.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Solid Phase ExtractionWater Pollutants, ChemicalRiversDrinking WaterLimit of DetectionReproducibility of ResultsLinear ModelsChromatography, High Pressure LiquidPharmaceutical PreparationsAdsorption

Stichwörter der Autor:innen

HPLC‐UVPT‐SPEcork powderemerging contaminantswater analysis

Substanzen

Water Pollutants, ChemicalDrinking WaterPharmaceutical Preparations

Autor:innen und Institutionen

  • Laboratory for Applications of Chemistry to Resources, Natural Substances and Environment (LACReSNE). Carthage University, Faculty of Sciences of Bizerte, Zarzouna, Carthage University, Zarzouna, Tunisia.
  • Laboratory of Environment Biomonitoring, Life Sciences Department, Faculty of Sciences Bizerte, University of Carthage, Zarzouna, Tunisia.
  • Useful Materials Laboratory (LMU), National Institute for Physical and Chemical Research and Analysis (INRAP), Ariana, Tunisia.

ORCID-Profile: Hassen Khazri

Zitieren

APA

Khazri, H., Touaylia, S., Trabelsi-Ayadi, M., Ternane, R., & Ghorbel-Abid, I. (2025). Natural Biosorbents for Detecting Emerging Contaminants in Tap and River Water via Pipette Tip Solid‐Phase Extraction (PT‐SPE). Biomedical Chromatography. https://doi.org/10.1002/bmc.70187

Vancouver

Khazri H, Touaylia S, Trabelsi-Ayadi M, Ternane R, Ghorbel-Abid I. Natural Biosorbents for Detecting Emerging Contaminants in Tap and River Water via Pipette Tip Solid‐Phase Extraction (PT‐SPE). Biomedical Chromatography. 2025. doi:10.1002/bmc.70187

BibTeX
@article{Khazri2025,
  author = {Khazri, Hassen and Touaylia, Samir and Trabelsi-Ayadi, Malika and Ternane, Riadh and Ghorbel-Abid, Ibtissem},
  title = {Natural Biosorbents for Detecting Emerging Contaminants in Tap and River Water via Pipette Tip Solid‐Phase Extraction (PT‐SPE)},
  journal = {Biomedical Chromatography},
  year = {2025},
  doi = {10.1002/bmc.70187}
}
Kostenlos starten →