EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A ng/L Level LC-MS Method Using Membrane SPE as Sampling Technology: Determination of Nine Halobenzoquinones in Potable Water

Qin Huang iD, Hua Zhou iD, Xianglun Wu, Jiaqi Jiang, Bingdong Zhan, Pinggu Wu

Molecules · 2024

DOI: 10.3390/molecules29122856 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, 2024. Verfasst von Qin Huang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Quzhou Center for Disease Control and Prevention, Quzhou 324000, China. Hauptthemen laut MEDLINE: Solid Phase Extraction, Benzoquinones, Drinking Water. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Quzhou City Science and Technology Program Competitive Project, Zhejiang Province Medical and Health Science and Technology Program, Zhejiang Province Medical and Health Science and Technology Program Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A promising method was established for the determination of nine halobenzoquinones (HBQs) in potable water by membrane solid-phase extraction (MSPE) pretreatment and the liquid chromatography–mass spectrometry (LC-MS) method. A 500 mL water sample was taken for enrichment by the SDB-RPS membrane, which was previously activated by methanol and ultrapure water. The sample was eluted with methanol and re-dissolved with the initial mobile phase after nitrogen blowing. Then, it was detected in negative ion mode using the working curve, and HBQs were quantified by the external standard method. The linearity was satisfactory in the concentration range of 4-1000 ng/L, with correlation coefficients of 0.9963~0.9994. The recoveries were 73.5~126.6% at three spiked levels, with relative standard deviations (RSDs) of 6.8~15.5%. The limits of detection (LOD, S/N = 3) values were 0.1~0.7 ng/L. The results demonstrate that the MSPE-LC-MS method is reliable, rapid, and sensitive for the simultaneous analysis of nine HBPs in potable water.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Solid Phase ExtractionBenzoquinonesDrinking WaterChromatography, LiquidMass SpectrometryLimit of DetectionWater Pollutants, ChemicalLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

halobenzoquinones (HBQs)liquid chromatography–mass spectrometry (LC-MS)membrane solid-phase extraction (MSPE)potable water

Substanzen

BenzoquinonesDrinking WaterWater Pollutants, Chemical

Autor:innen und Institutionen

  • Quzhou Center for Disease Control and Prevention, Quzhou 324000, China.
  • Lab of Physicochemical Research, Department of Physicochemical & Toxicology, Zhejiang Provincial Centre for Disease Control and Prevention, Hangzhou 310051, China.

ORCID-Profile: Qin Huang, Hua Zhou

Förderung

  • Quzhou City Science and Technology Program Competitive Project
  • Zhejiang Province Medical and Health Science and Technology Program
  • Zhejiang Province Medical and Health Science and Technology Program Project

Zitieren

APA

Huang, Q., Zhou, H., Wu, X., Jiang, J., Zhan, B., & Wu, P. (2024). A ng/L Level LC-MS Method Using Membrane SPE as Sampling Technology: Determination of Nine Halobenzoquinones in Potable Water. Molecules. https://doi.org/10.3390/molecules29122856

Vancouver

Huang Q, Zhou H, Wu X, Jiang J, Zhan B, Wu P. A ng/L Level LC-MS Method Using Membrane SPE as Sampling Technology: Determination of Nine Halobenzoquinones in Potable Water. Molecules. 2024. doi:10.3390/molecules29122856

BibTeX
@article{Huang2024,
  author = {Huang, Qin and Zhou, Hua and Wu, Xianglun and Jiang, Jiaqi and Zhan, Bingdong and Wu, Pinggu},
  title = {A ng/L Level LC-MS Method Using Membrane SPE as Sampling Technology: Determination of Nine Halobenzoquinones in Potable Water},
  journal = {Molecules},
  year = {2024},
  doi = {10.3390/molecules29122856}
}
Kostenlos starten →