The Simultaneous Detection of Dopamine and Uric Acid In Vivo Based on a 3D Reduced Graphene Oxide–MXene Composite Electrode
Molecules · 24.04.2024 · 29 (9) · 1936
DOI: 10.3390/molecules29091936 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, online erschienen am 24.04.2024. Verfasst von Lingjun Shang und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Medical Engineering, Xinxiang Medical University, Xinxiang 453003, China. Hauptthemen laut MEDLINE: Graphite, Uric Acid, Dopamine, Electrodes. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Natural Science Foundation of Henan Province, Open Program of Henan Key Laboratory of Biological Psychiatry, Science and Technology Tackling of Henan.
Abstract (Originalsprache)
Dopamine (DA) and uric acid (UA) are essential for many physiological processes in the human body. Abnormal levels of DA and UA can lead to multiple diseases, such as Parkinson’s disease and gout. In this work, a three-dimensional reduced graphene oxide–MXene (3D rGO-Ti3C2) composite electrode was prepared using a simple one-step hydrothermal reduction process, which could separate the oxidation potentials of DA and UA, enabling the simultaneous detection of DA and UA. The 3D rGO-Ti3C2 electrode exhibited excellent electrocatalytic activity towards both DA and UA. In 0.01 M PBS solution, the linear range of DA was 0.5–500 µM with a sensitivity of 0.74 µA·µM−1·cm−2 and a detection limit of 0.056 µM (S/N = 3), while the linear range of UA was 0.5–60 µM and 80–450 µM, with sensitivity of 2.96 and 0.81 µA·µM−1·cm−2, respectively, and a detection limit of 0.086 µM (S/N = 3). In 10% fetal bovine serum (FBS) solution, the linear range of DA was 0.5–500 µM with a sensitivity of 0.41 µA·µM−1·cm−2 and a detection limit of 0.091 µM (S/N = 3). The linear range of UA was 2–500 µM with a sensitivity of 0.11 µA·µM−1·cm−2 and a detection limit of 0.6 µM (S/N = 3). The modified electrode exhibited advantages such as high sensitivity, a strong anti-interference capability, and good repeatability. Furthermore, the modified electrode was successfully used for DA measurement in vivo. This could present a simple reliable route for neurotransmitter detection in neuroscience.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Medical Engineering, Xinxiang Medical University, Xinxiang 453003, China.
ORCID-Profile: Xuming Sun, Qiongqiong Ren
Förderung
- the Natural Science Foundation of Henan Province
- Open Program of Henan Key Laboratory of Biological Psychiatry
- Science and Technology Tackling of Henan
- Natural Science Foundation of Henan Province
Zitieren
APA
Shang, L., Li, R., Li, H., Yu, S., Sun, X., Yu, Y., & Ren, Q. (2024). The Simultaneous Detection of Dopamine and Uric Acid In Vivo Based on a 3D Reduced Graphene Oxide–MXene Composite Electrode. Molecules, 29(9), 1936. https://doi.org/10.3390/molecules29091936
Vancouver
Shang L, Li R, Li H, Yu S, Sun X, Yu Y, et al. The Simultaneous Detection of Dopamine and Uric Acid In Vivo Based on a 3D Reduced Graphene Oxide–MXene Composite Electrode. Molecules. 2024;29(9):1936. doi:10.3390/molecules29091936
BibTeX
@article{Shang2024,
author = {Shang, Lingjun and Li, Ruijiao and Li, Haojie and Yu, Shuaiqun and Sun, Xuming and Yu, Yi and Ren, Qiongqiong},
title = {The Simultaneous Detection of Dopamine and Uric Acid In Vivo Based on a 3D Reduced Graphene Oxide–MXene Composite Electrode},
journal = {Molecules},
year = {2024},
volume = {29},
number = {9},
pages = {1936},
doi = {10.3390/molecules29091936}
}
EUVIMED