Few Layer Ti3C2 MXene-Based Label-Free Aptasensor for Ultrasensitive Determination of Chloramphenicol in Milk
Molecules · 15.08.2023 · 28 (16) · 6074
DOI: 10.3390/molecules28166074 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, online erschienen am 15.08.2023. Verfasst von Fang Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Key Laboratory of Food Biotechnology, College of Biotechnology and Food Science, Tianjin University of Commerce, Tianjin 300134, China. Hauptthemen laut MEDLINE: Chloramphenicol, Milk. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, Tianjin Science and Technology planning project.
Abstract (Originalsprache)
Quantitative detection of veterinary drug residues in animal-derived food is of great significance. In this work, a simple and label-free electrochemical aptasensor for the highly sensitive detection of chloramphenicol (CAP) in milk was successfully developed based on a new biosensing method, where the single- or few-layer Ti3C2 MXene nanosheets functionalized via the specific aptamer by self-assembly were used as electrode modifiers for a glassy carbon electrode (aptamer/Ti3C2 MXene/GCE). Differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), scanning electron microscopy (SEM), atomic force microscope (AFM), and so on were utilized for electrochemical and morphological characterization. Under the optimized conditions, the constructed aptasensor exhibited excellent performance with a wider linearity to CAP in the range from 10 fM to 1 μM and a low detection limit of 1 fM. Aptamer/Ti3C2 MXene/GCE demonstrated remarkable selectivity over other potentially interfering antibiotics, as well as exceptional reproducibility and stability. In addition, the aptasensor was successfully applied to determine CAP in milk with acceptable recovery values of 96.13% to 108.15% and relative standard deviations below 9%. Therefore, the proposed electrochemical aptasensor is an excellent alternative for determining CAP in food samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Tianjin Key Laboratory of Food Biotechnology, College of Biotechnology and Food Science, Tianjin University of Commerce, Tianjin 300134, China.
Förderung
- National Key Research and Development Program of China
- Tianjin Science and Technology planning project
Zitieren
APA
Li, F., Xiong, S., Zhao, P., Dong, P., & Wu, Z. (2023). Few Layer Ti3C2 MXene-Based Label-Free Aptasensor for Ultrasensitive Determination of Chloramphenicol in Milk. Molecules, 28(16), 6074. https://doi.org/10.3390/molecules28166074
Vancouver
Li F, Xiong S, Zhao P, Dong P, Wu Z. Few Layer Ti3C2 MXene-Based Label-Free Aptasensor for Ultrasensitive Determination of Chloramphenicol in Milk. Molecules. 2023;28(16):6074. doi:10.3390/molecules28166074
BibTeX
@article{Li2023,
author = {Li, Fang and Xiong, Shuyue and Zhao, Pei and Dong, Panpan and Wu, Zijian},
title = {Few Layer Ti3C2 MXene-Based Label-Free Aptasensor for Ultrasensitive Determination of Chloramphenicol in Milk},
journal = {Molecules},
year = {2023},
volume = {28},
number = {16},
pages = {6074},
doi = {10.3390/molecules28166074}
}
EUVIMED