Highly sensitive label-free photoelectrochemical aptasensor based on Cu2MoS4@Ti3C2Tx MXene heterojunction for tetracycline detection in milk

Yuying Xu, Lijuan Chen, Xiaohui Guo, Jian Zhang, Xiaobing Guo, Ziqian He, Jiani Zhang, Dongxue Han

Microchimica Acta · 2025

DOI: 10.1007/s00604-025-07016-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Yuying Xu und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Food Science and Technology, Shihezi University, Shihezi, 832003, Xinjiang, China. Hauptthemen laut MEDLINE: Milk, Aptamers, Nucleotide, Tetracycline, Electrochemical Techniques. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A label-free photoelectrochemical (PEC) biosensing strategy was constructed based on a Cu2MoS4@Ti3C2Tx MXene heterojunction for the sensitive detection of tetracycline (TC) in milk. The Cu2MoS4@Ti3C2Tx MXene heterojunction substantially facilitates the separation of photogenerated electron-hole pairs, a key element in enhancing the photocurrent response. Cu2MoS4, renowned for its visible-light absorption and photocatalytic properties, is combined synergistically with Ti3C2Tx MXene, contributing a large surface area and outstanding electrical conductivity. The heterojunction not only elevates photocatalytic efficiency but also provides abundant π-π stacking sites on the surface of Ti3C2Tx MXene. These sites enable the direct immobilization of the TC aptamer without chemical modification, thereby minimizing marker interference and improving the detection accuracy. Furthermore, the heterojunction structure broadens the light-absorption spectrum and enhances charge-transfer efficiency, resulting in a higher photocurrent response. The proposed PEC aptasensor demonstrates a favorable linear response to TC within the concentration range 5 to 300 nM, with a detection limit of 1.24 nM. These results are comparable to those achieved by high-performance liquid chromatography. This study is expected to pioneer a novel approach for the design of a label-free PEC aptasensor applicable to the bioanalysis of food samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MilkAptamers, NucleotideTetracyclineElectrochemical TechniquesBiosensing TechniquesAnti-Bacterial AgentsAnimalsLimit of DetectionCopperFood ContaminationTitaniumPhotochemical ProcessesMolybdenumNitritesTransition Elements

Stichwörter der Autor:innen

Cu2MoS4@Ti3C2Tx MXene heterojunctionLabel-freePhotoactive materialPhotoelectrochemical aptasensorTetracycline detection

Substanzen

Aptamers, NucleotideTetracyclineCopperTitaniumMolybdenumAnti-Bacterial AgentsMXeneNitritesTransition Elements

Autor:innen und Institutionen

  • School of Food Science and Technology, Shihezi University, Shihezi, 832003, Xinjiang, China.
  • Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Ch…
  • Key Laboratory of Agricultural Product Processing and Quality Control of Specialty (Co-Construction By Ministry and Province), Shihezi, 832003, Xinjiang, China.
  • Key Laboratory for Food Nutrition and Safety Control of Xinjiang Production and Construction Corps, Shihezi University, Shihezi, 832003, Xinjiang, China.
  • School of Food Science and Technology, Shihezi University, Shihezi, 832003, Xinjiang, China. shzugxb@163.com.
  • Key Laboratory of Agricultural Product Processing and Quality Control of Specialty (Co-Construction By Ministry and Province), Shihezi, 832003, Xinjiang, China. shzugxb@163.com.

Zitieren

APA

Xu, Y., Chen, L., Guo, X., Zhang, J., Guo, X., He, Z., Zhang, J., & Han, D. (2025). Highly sensitive label-free photoelectrochemical aptasensor based on Cu2MoS4@Ti3C2Tx MXene heterojunction for tetracycline detection in milk. Microchimica Acta. https://doi.org/10.1007/s00604-025-07016-0

Vancouver

Xu Y, Chen L, Guo X, Zhang J, Guo X, He Z, et al. Highly sensitive label-free photoelectrochemical aptasensor based on Cu2MoS4@Ti3C2Tx MXene heterojunction for tetracycline detection in milk. Microchimica Acta. 2025. doi:10.1007/s00604-025-07016-0

BibTeX
@article{Xu2025,
  author = {Xu, Yuying and Chen, Lijuan and Guo, Xiaohui and Zhang, Jian and Guo, Xiaobing and He, Ziqian and Zhang, Jiani and Han, Dongxue},
  title = {Highly sensitive label-free photoelectrochemical aptasensor based on Cu2MoS4@Ti3C2Tx MXene heterojunction for tetracycline detection in milk},
  journal = {Microchimica Acta},
  year = {2025},
  doi = {10.1007/s00604-025-07016-0}
}
Kostenlos starten →