Enhanced-Precision Measurement of Glutathionyl Hemoglobin by MALDI-ToF MS
Molecules · 2023
DOI: 10.3390/molecules28020497 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, 2023. Verfasst von Federico Maria Rubino und 5 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory for Analytical Toxicology and Metabonomics, Department of Health Sciences, Università degli Studi di Milano, v. A. di Rudinì 8, 20142 Mila…. Hauptthemen laut MEDLINE: Hemoglobins, Glutathione. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Concorde Project, HITCoA FISR-COVID-19 Project.
Abstract (Originalsprache)
Glutathionyl-hemoglobin (HbSSG) is used as a human biomarker to pinpoint systemic oxidative stress caused by various pathological conditions, noxious lifestyles, and exposure to drugs and environmental or workplace toxicants. Measurement by MALDI mass spectrometry is most frequently used, however, the method suffers from excessive uncontrolled variability. This article describes the improvement of a MALDI-ToF mass spectrometry method for HbSSG measurement through enhanced precision, based on strict control of sample preparation steps and spreadsheet-based data analysis. This improved method displays enhanced precision in the analysis of several hundred samples deriving from studies in different classes of healthy and diseased human subjects. Levels span from 0.5% (lower limit of detection) up to 30%, measured with a precision (as SE%) < 0.5%. We optimized this global procedure to improve data quality and to enable the Operator to work with a reduced physical and psychological strain. Application of this method, for which full instruction and the data analysis spreadsheet are supplied, can encourage the exploitation of HbSSG to study human oxidative stress in a variety of pathological and living conditions and to rationally test the efficacy of antioxidant measures and treatments in the frame of health promotion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratory for Analytical Toxicology and Metabonomics, Department of Health Sciences, Università degli Studi di Milano, v. A. di Rudinì 8, 20142 Milan, Italy.
- Department of Health Sciences, Università degli Studi di Milano, 20146 Milan, Italy.
- DAN Europe Research Division, 64026 Roseto degli Abruzzi, Italy.
- MAGI Group, 25010 San Felice del Benaco, Italy.
- Laboratory for Medical Mass Spectrometry, Department of Health Sciences, Università degli Studi di Milano, 20146 Milan, Italy.
ORCID-Profile: Federico Maria Rubino, Sara Ottolenghi, Claudio Maioli, Michele Samaja, Rita Paroni
Förderung
- Concorde Project
- HITCoA FISR-COVID-19 Project
Zitieren
APA
Rubino, F. M., Ottolenghi, S., Brizzolari, A., Maioli, C., Samaja, M., & Paroni, R. (2023). Enhanced-Precision Measurement of Glutathionyl Hemoglobin by MALDI-ToF MS. Molecules. https://doi.org/10.3390/molecules28020497
Vancouver
Rubino FM, Ottolenghi S, Brizzolari A, Maioli C, Samaja M, Paroni R. Enhanced-Precision Measurement of Glutathionyl Hemoglobin by MALDI-ToF MS. Molecules. 2023. doi:10.3390/molecules28020497
BibTeX
@article{Rubino2023,
author = {Rubino, Federico Maria and Ottolenghi, Sara and Brizzolari, Andrea and Maioli, Claudio and Samaja, Michele and Paroni, Rita},
title = {Enhanced-Precision Measurement of Glutathionyl Hemoglobin by MALDI-ToF MS},
journal = {Molecules},
year = {2023},
doi = {10.3390/molecules28020497}
}
EUVIMED